Pulmonary artery wedge catheter position as a site for injection of indicator substance.

نویسندگان

  • G G ROWE
  • C A CASTILLO
  • G M MAXWELL
  • C W CRUMPTON
  • R J BOTHAM
چکیده

THE use of indicator-dilution curves during cardiac catheterization has greatly clarified the hemodynamics of various congenital cardiovascular malformations.1 2 As presently used, the combination of indicatordilution curves and oximetry is usually sufficient to establish a definitive diagnosis. In some subjects with small left-to-right intracardiac shunts, however, the usual diagnostic methods are inadequate. In attempts to prove the existence of small shunits additional diagnostic procedures may be required such as the placement of 2 catheters in the right side of the heart3 or catheterization of the left side of the heart.4 The present study reports the injection of indicator substance with the catheter in the pulmonary wedge position as an additional diagnostic aid.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulmonary wedge injections yielding left-sided echocardiographic contrast.

Ultrasound contrast on the left side of the heart without the need for left heart catheterisation was achieved by hand injections of 8 to 10 ml 5 per cent dextrose solution through a catheter in the pulmonary wedge position. Injections were performed in 18 patients undergoing routine cardiac catheterisation and M-mode or two-dimensional echocardiography was used. An adequate wedge position was ...

متن کامل

Influence of catheter tip position on pulmonary wedge pressures.

• Simultaneously recorded left atrial and pulmonary artery wedge pressures demonstrate that the left atrial pressure pulse can be transmitted across the pulmonary capillary bed and recorded by the wedged catheter." However, such satisfactory wedge tracings are not always obtainable, and in many trials the tracing is featureless, damped or distorted by artifacts and obviously is not a true refle...

متن کامل

A severe complication of pulmonary vein angiography.

A pulmonary vein angiogram was performed using a pressure injection with the tip of an end and side hole catheter in a near-wedge position; extravasation of contrast material into a bronchus occurred, causing severe bronchoconstriction. It may be possible to avoid this complication by the use of an end hole balloon catheter in the wedge position, slow flow rates of contrast material, and low pr...

متن کامل

The interrelations of the pulmonary arterial and venous wedge pressures.

APRESSURE recorded through a cardiac catheter wedged tightly in a small . pulmonary artery has been referred to as a "capillary," "venous" or "wedge" pressure. On the other hand, a pressure recorded through a cardiac catheter wedged into a pulmonary vein during thoracotomy and in intact animals has been referred to as a pulmonary venous wedge pressure'. Some investigators have found good correl...

متن کامل

A technique for unknotting an intracardiac flow-directed balloon catheter.

Described is an unusual complication occurring during right-sided cardiac catheterization using a 7F flow-directed balloon catheter. During an attempt to direct the catheter from the main pulmonary artery into the pulmonary wedge position, the tip became entangled in a loop of catheter and knotted. Initially, all attempts to unknot or remove the catheter failed. A movable core guide wire was pa...

متن کامل