Measurement and cancellation of the cold collision frequency shift in an 87Rb fountain clock

نویسندگان

  • Fertig
  • Gibble
چکیده

We measure a cold collision frequency shift in an 87Rb fountain clock that is fractionally 30 times smaller than that for Cs. The shift is -0.38(8) mHz for a density of 1.0(6)x10(9) cm(-3). We study the cavity pulling of the atomic transition and use it to cancel the cold collision shift. We also measure the partial frequency shifts of each clock state finding 2(lambda(10)-lambda(20))/(lambda(10)+lambda(20)) = 0.1(6).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cold collision frequency shifts in a 87Rb atomic fountain.

We present measurements of cavity frequency pulling and collisional frequency shifts in a 87Rb fountain with a frequency resolution of 3x10(-16). Agreement with theory is found for the cavity pulling and the measured collisional shifts. The clock shift is found at least 50 times smaller than in 133Cs.

متن کامل

Cold-collision-shift cancellation and inelastic scattering in a Yb optical lattice clock

Recently, p-wave cold collisions were shown to dominate the density-dependent shift of the clock transition frequency in a 171Yb optical lattice clock. Here we demonstrate that by operating such a system at the proper excitation fraction, the cold-collision shift is canceled below the 5 × 10−18 fractional frequency level. We report inelastic two-body loss rates for P0 -P0 and S0 -P0 scattering....

متن کامل

Cancellation of the collisional frequency shift in caesium fountain clocks.

We have observed that the collisional frequency shift in primary caesium fountain clocks varies with the clock state population composition and, in particular, is zero for a given fraction of the |F=4,mF=0) atoms, depending on the initial cloud parameters. We present a theoretical model explaining our observations. The possibility of the collisional shift cancellation implies an improvement in ...

متن کامل

NPL Cs fountain frequency standards and the quest for the ultimate accuracy

NPL operates a system of two primary caesium fountain clocks consisting of a fully characterised standard NPL-CsF2 together with a new standard NPL-CsF3, which has recently become operational. Both fountains feature a single-stage vapour-loaded magneto-optical trap as the source of cold atoms and an approximate cancellation of the potentially large cold collision frequency shift. As a result, t...

متن کامل

Differential light-shift cancellation in a magnetic-field-insensitive transition of 87rb.

The precise measurement of transition frequencies of trapped atomic samples is susceptible to inaccuracy arising from the inhomogeneous differential shift of the relevant energy levels in the presence of the trapping fields. We demonstrate near-complete cancellation of the differential ac Stark shift ("light shift") of a two-photon magnetic-field-insensitive microwave hyperfine (clock) transiti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Physical review letters

دوره 85 8  شماره 

صفحات  -

تاریخ انتشار 2000