Automated ocular artifact removal: comparing regression and component-based methods
نویسندگان
چکیده
Objective: The aim is to compare various fully automated methods for reducing ocular artifacts from EEG recordings. Methods: Seven automated methods including regression, six component-based methods for reducing ocular artifacts have been applied to 36 data sets from two different labs. The influence of various noise sources is analyzed and the ratio between corrected and uncorrected EEG spectra, has been used to quantify the distortion. Results: The results show that not only regression but also component-based methods are vulnerable to overor under-compensation and can cause significant distortion of EEG. Despite common belief, component-based methods did not demonstrate an advantage over the simple regression method. Conclusion: The newly proposed evaluation criterion showed to be an effective approach to evaluate 252 results from 36 data sets and 7 different methods. Significance: Currently, the regression method provides the most robust and stable results and is therefore the state-of-the-art-method for fully automated reduction of ocular artifacts.
منابع مشابه
Automatic correction of ocular artifacts in the EEG: a comparison of regression-based and component-based methods.
A variety of procedures have been proposed to correct ocular artifacts in the electroencephalogram (EEG), including methods based on regression, principal components analysis (PCA) and independent component analysis (ICA). The current study compared these three methods, and it evaluated a modified regression approach using Bayesian adaptive regression splines to filter the electrooculogram (EOG...
متن کاملComparison of ICA and WT with S-transform based method for removal of ocular artifact from EEG signals
Ocular artifacts are most unwanted disturbance in electroencephalograph (EEG) signals. These are characterized by high amplitude but have overlapping frequency band with the useful signal. Hence, it is difficult to remove the ocular artifacts by traditional filtering methods. This paper proposes a new approach of artifact removal using S-transform (ST). It provides an instantaneous time-frequen...
متن کاملCombining EEG and eye tracking: identification, characterization, and correction of eye movement artifacts in electroencephalographic data
Eye movements introduce large artifacts to electroencephalographic recordings (EEG) and thus render data analysis difficult or even impossible. Trials contaminated by eye movement and blink artifacts have to be discarded, hence in standard EEG-paradigms subjects are required to fixate on the screen. To overcome this restriction, several correction methods including regression and blind source s...
متن کاملECG Artifact Removal from Surface EMG Signal Using an Automated Method Based on Wavelet-ICA
This study aims at proposing an efficient method for automated electrocardiography (ECG) artifact removal from surface electromyography (EMG) signals recorded from upper trunk muscles. Wavelet transform is applied to the simulated data set of corrupted surface EMG signals to create multidimensional signal. Afterward, independent component analysis (ICA) is used to separate ECG artifact componen...
متن کاملJournal: Clin
Objective: The aim is to compare various fully automated methods for reducing ocular artifacts from EEG recordings. Methods: Seven automated methods including regression, six component-based methods for reducing ocular artifacts have been applied to 36 data sets from two different labs. The influence of various noise sources is analyzed and the ratio between corrected and uncorrected EEG spectr...