Sequential determination of trace amounts of iron and copper in water samples by flow injection analysis with catalytic spectrophotometric detection.

نویسندگان

  • Sarawut Lunvongsa
  • Tomonori Tsuboi
  • Shoji Motomizu
چکیده

A simple flow injection analysis (FIA) method is described for the sequential determination of iron and copper. The detection method for iron and copper is based on their catalytic activities in the oxidation reaction of N,N-dimethyl-p-phenylenediamine (DPD) with hydrogen peroxide. The sequential determination of iron and copper can be carried out by injecting two sample plugs into the FIA system, sequentially. One injection does not contain triethylenetetramine (TETA), and is used for the sum of iron and copper concentration; the other which contains TETA is used only for the iron concentration. For iron determination, TETA is used as a masking agent of copper. The difference in peak height can be used for the calculation of copper concentration. Under the optimal conditions, the detection limits (3sigma) of 0.01 and 0.07 microg L(-1) were obtained for iron and copper, respectively. The proposed method can be applied to the determination of iron and copper in tap water and bottled-drinking mineral water samples. Good recoveries of the method, 98-103% for iron and 98-106% for copper, were achieved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultra-trace Determination of Palladium(II) by Spectrophotometric Flow Injection Analysis

Nowadays, palladium compounds due to their especial characteristics used in different industries, mainly in electrical power sources and chemical productions as a catalyst. Therefore, Pd concentration is increasing in our around that can be contaminant our environment due its toxic effects. In this work, a simple, selective and rapid flow injection method of analysis (FIA) has been developed fo...

متن کامل

Catalytic flow-injection determination of sub-ppb copper(II) using the redox reaction of cysteine with iron(III) in the presence of 2,4,6-tris(2-pyridyl)-1,3,5-triazine.

A kinetic-catalytic spectrophotometric flow-injection method was developed for the rapid and sensitive determination of trace amounts of copper(II). The method is based on the catalytic effect of copper(II) on the redox reaction of cysteine with iron(III). Iron(II) produced by the catalytic reaction reacts with 2,4,6-tris(2-pyridyl)-1,3,5-triazine (TPTZ) to form the iron(II)-TPTZ complex (lambd...

متن کامل

Catalytic-Spectrophotometric Determination of Trace Amounts of Manganese(II) by Catalysis of the Oxidation of Ferroin with Periodate

A catalytic spectrophotometric method for determination of ultra-trace quantities of manganese(II) id described. The method is based on the catalytic effect of manganese(II) on the oxidation reaction of ferroin by potassium periodate in acidic media. The reaction is monitored spectrophotometrically at 510 nm by a slope method and Mn(II) is determinable in the range of 1-1000ngmL-1</sup...

متن کامل

Catalytic Kinetic Determination of Silver through its Catalytic Effect on Congo Red-Peroxodisulphate Reaction

A kinetic-spectrophotometric procedure is reported for determination of trace amounts of Ag(I). This method is based on catalytic effect of silver ion on the oxidation of congo red by potassium peroxodisulphate at pH=3.4 and 30 oC in the presence of 1,10-phenanthroline as an activator. The reaction was followed spectrophotometrically by measuring the rate of change in absorbance ...

متن کامل

A NOVEL AND HIGHLY SENSITIVE CATALYTIC METHOD FOR THE DETERMINATION OF ULTRA TRACE AMOUNTS OF CERIUM WITH SPECTROPHOTOMETRIC DETECTION

Cerium (IV) has a catalytic effect on the very slow redox reaction between gallocyanine and bromate in acidic media. The reaction was monitored spectrophotometrically at 525 nm by a fixed time method of 4.0 rnin from initiation of the reaction. The decrease in absorbance at 525 nm is proportional to the Ce (IV) concentration in the range of 0.005-1.000 and 1.00-10.00 pg. ml-l. The limit of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 22 1  شماره 

صفحات  -

تاریخ انتشار 2006