Simple real-time noise removal in intensified low-light-level television images.
نویسندگان
چکیده
A simple and novel real-time interframe operator substantially reduces short-lived noisy scintillations in low-lightlevel video imaging systems that use image intensifiers.
منابع مشابه
Advanced Image Haze Removal Using Denoising and Dehazing Algorithm with Compression
1 PG Scholar , Paavai Engineering College, Namakkal, 2 M .E., Associate professor ,Department of ECE, Paavai engineering college,Namakkal Received 25 November 2015; Accepted 4 December 2015 ABSTRACT: Single image haze removal has been a demanding problem due to its ill-posed nature. Images captured in hazy weather environment often suffer from poor illumination conditions that will create a lot...
متن کاملA Denoising Scheme for Randomly Clustered Noise Removal in ICCD Sensing Image
An Intensified Charge-Coupled Device (ICCD) image is captured by the ICCD image sensor in extremely low-light conditions. Its noise has two distinctive characteristics. (a) Different from the independent identically distributed (i.i.d.) noise in natural image, the noise in the ICCD sensing image is spatially clustered, which induces unexpected structure information; (b) The pattern of the clust...
متن کاملSimulated intensified images
The most straightforward way to describe the performance of an image intensifier tube, especially under adverse conditions, is to predict the image it yields. In this work we have developed two different methods to provide realistic simulated images in low light level conditions: 1) Approximate Physical Model. A classical approach based on the simulation of the different degradation sources. It...
متن کاملRandom-Valued Impulse Noise Reduction in Medical Images by Using Double-Checked Fast Adaptive Median Filter
Median-filters have been used for a very long time as an influential non-linear technique to removal of impulse noise. There have been many suggestions regarding the filters that can get rid of this noise while keeping the necessary details. However, these filters have one thing in common: They are only effective at low noise rate and thus are practical only for low-noise in image. Another thin...
متن کاملروشی نوین در کاهش نوفه رایسین از مقدار بزرگی سیگنال دیفیوژن در تصویربرداری تشدید مغناطیسی (MRI)
The true MR signal intensity extracted from noisy MR magnitude images is biased with the Rician noise caused by noise rectification in the magnitude calculation for low intensity pixels. This noise is more problematic when a quantitative analysis is performed based on the magnitude images with low SNR(<3.0). In such cases, the received signal for both the real and imaginary components will fluc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Applied optics
دوره 31 17 شماره
صفحات -
تاریخ انتشار 1992