Differences in Blood Pressure Measurements Obtained Using an Automatic Oscillometric Sphygmomanometer Depending on Clothes-Wearing Status

نویسندگان

  • Ji Hoon Ki
  • Mi Kyeong Oh
  • Soo Hee Lee
چکیده

BACKGROUND According to the current guidelines for blood pressure monitoring, clinicians are recommended to measure blood pressure by completely exposing the upper arm. However, it is a common practice that blood pressure is measured with the cuff placed over the sleeve or with the sleeve rolled up. We therefore conducted this study to examine whether there are any differences in blood pressure measurements among the three different settings: the sleeve group, the rolled sleeve group, and the bare arm group. METHODS We conducted the current study in 141 male and female adult patients who visited our clinical department. In these patients, we took repeatedly blood pressure measurements using the same automatic oscillometric device on three different settings. Then, we analyzed the results with the use of randomized block design analysis of variance. RESULTS The mean values of systolic blood pressure (SBP) between the first reading and those of the second reading were 128.5 ± 10.6 mm Hg in the sleeve group, 128.3 ± 10.8 mm Hg in the rolled sleeve group, and 128.3 ± 10.7 mm Hg in the bare arm group. These results indicate that there were no significant differences among the three groups (P = 0.32). In addition, the mean values of diastolic blood pressure (DBP) between the first reading and those of the second reading were 80.7 ± 6.1 mm Hg in the sleeve group, 80.7 ± 6.1 mm Hg in the rolled sleeve group, and 80.6 ± 5.9 mm Hg in the bare arm group. These results indicate that there were no significant differences among the three groups (P = 0.77). In addition, based on the age, sex, past or current history of hypertension or diabetes mellitus, the thickness of sleeve, weight, a drinking history, and a smoking history, there were no significant differences in SBP and DBP among the three groups. CONCLUSION There were no significant differences in blood pressure measurements between the three different settings (the sleeve group, the rolled sleeve group, and the bare arm group).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improving the Design of Blood Pressure and Blood Saturation Monitors

A blood pressure monitor or sphygmomanometer can be either manual or automatic, employing respectively either the auscultatory method or the oscillometric method. The manual version of the sphygmomanometer involves an inflatable cuff with a stethoscope adopted to detect the sounds generated by the arterial walls to measure blood pressure in an artery. An automatic sphygmomanometer can be effect...

متن کامل

Arterial stiffness as underlying mechanism of disagreement between an oscillometric blood pressure monitor and a sphygmomanometer.

Oscillometric blood pressure devices tend to overestimate systolic blood pressure and underestimate diastolic blood pressure compared with sphygmomanometers. Recent studies indicate that discrepancies in performance between these devices may differ between healthy and diabetic subjects. Arterial stiffness in diabetics could be the underlying factor explaining these differences. We studied diffe...

متن کامل

Arterial blood pressure of term newborns during the first week of life.

The progressive behavior of the blood pressure of term newborns during the first week of life was assessed by the simultaneous use of oscillometric and Doppler methods. A total of 174 term neonates born at the Municipal Hospital Odilon Behrens in Belo Horizonte, from March 1996 to February 1997, were prospectively assessed. The oscillometric and Doppler ultrasonic methods were simultaneously us...

متن کامل

Comparison of auscultatory and oscillometric BP measurements in children with obesity and their effect on the diagnosis of arterial hypertension.

OBJECTIVE The level of agreement between two blood pressure (BP) reading methods, auscultatory vs oscillometric, was examined using a mercury sphygmomanometer and an electronic device in children and adolescents with different levels of obesity. The readings were compared to determine their impact on the diagnosis of pre-hypertension/hypertension. METHODS Blood pressure readings were taken in...

متن کامل

The accuracy of the Marshall 85 oscillometric sphygmomanometer in the ambulatory care setting.

The purpose of this study was to evaluate a partially automated sphygmomanometer for accuracy in the ambulatory care setting. Patients seen in 80 consecutive office visits served as subjects. Blood pressures were measured simultaneously under standard conditions. The oscillometric test instrument and a standard mercury manometer were connected with a Y tube. Paired t-tests were used to determin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 34  شماره 

صفحات  -

تاریخ انتشار 2013