Iodine based radiopacity of experimental blood clots for testing of mechanical thrombectomy devices

نویسندگان

  • Zhong Hua Luo
  • Alex Chung
  • Gibok Choi
  • Yih Huie Lin
  • Huajin Pang
  • Barry T. Uchida
  • Dusan Pavcnik
  • Miran Jeromel
  • Frederick S. Keller
  • Josef Rösch
چکیده

BACKGROUND Barium sulfate powder used for radiopacity of experimental blood clots (EBCs) for testing mechanical thrombectomy devices (MTD) has negative effects on EBCs mechanical properties. In vitro and in vivo exploration was performed to determine if the iodine based contrast medium will have less negative effects on the EBCs than barium. MATERIALS AND METHODS Fresh blood from 2 swine was used to create fibrinogen enhanced and thrombin initiated EBC in tubes. Iodine radiopacity was achieved by mixing the blood with 65% Iohexol or by soaking the EBCs for 2 or 24 hours in Iohexol. The EBCs opacified with barium served as controls. In vitro study: The EBCs were subjected to four tests, manual elongation, catheter injection, radiopacity and contrast wash out tests. In vivo study: The common carotid arteries of 2 swine were embolized by either barium EBC or EBC soaked for 24 hours in Iohexol. The duration of radiopacity of the different EBCs was compared. RESULTS The EBCs opacified with Iohexol initially had higher radiopacity than the barium opacified EBCs. However, their opacity rapidly decreased with saline soaking and, particularly, after they were embolized in live animals. The mechanical properties of Iohexol opacified EBCs were inferior to barium opacified EBCs. The Iohexol mixed EBCs were less firm and elastic and half of them fragmented during catheter injection. The Iohexol soaked EBCs exhibited decreased tensile strength and elasticity compared to the barium EBCs. CONCLUSIONS Compared to barium, iodine based contrast medium does not offer any advantage for opacifying EBCs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental evaluation of stent retrievers’ mechanical properties and effectiveness

BACKGROUND Five randomized controlled trials recently appeared in the literature demonstrating that early mechanical thrombectomy in patients with acute ischemic stroke is significantly related to an improved outcome. Stent retrievers are accepted as the most effective devices for intracranial thrombectomy. OBJECTIVE To analyze the mechanical properties of stent retrievers, their behavior dur...

متن کامل

2011 UKSim 13th International Conference on Modelling and Simulation

According to the World Health Organization [1] , 15 million people suffer stroke worldwide each year; of these, 5 million die and 5 million are permanently disabled. Stroke is therefore a major cause of mortality world-wide. The majority of strokes are caused by a blood clot that occludes an artery in the brain, and although thrombolytic agents such as Alteplase are used to dissolve clots that ...

متن کامل

Immunohistochemical Analysis of Cerebral Thrombi Retrieved by Mechanical Thrombectomy from Patients with Acute Ischemic Stroke.

Mechanical thrombectomy is a novel treatment option for patients with acute ischemic stroke (AIS). Only a few studies have previously suggested strategies to categorize retrieved clots according to their histologic composition. However, these reports did not analyze potential biomarkers that are of importance in stroke-related inflammation. We therefore histopathologically investigated 37 intra...

متن کامل

Inflammatory mediator expression within retrieved clots in acute ischemic stroke

Objective In this study we investigate the association between the expression of inflammatory mediators measured in clots retrieved by mechanical thrombectomy, stroke etiology, and the susceptibility vessel sign (SVS) on gradient-echo (GRE) MR imaging in acute ischemic stroke patients. Methods We performed molecular analysis of intracranial clots retrieved by mechanical thrombectomy from 82 p...

متن کامل

A novel method of thrombus preparation for use in a swine model for evaluation of thrombectomy devices.

We report the development of a novel technique of thrombus preparation for use in a swine model for evaluation of thrombectomy devices. The experimental thrombus prepared using plain sedimentation showed mechanical stability due to its solid fibrin-rich component. The thrombus also showed histologic similarity to the typical thromboemboli recovered from patients with stroke in the course of the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 47  شماره 

صفحات  -