A chemiluminescence reagent free method for the determination of captopril in medicine and urine samples by using trivalent silver

نویسندگان

  • Zhaofu Fu
  • Wanting Huang
  • Gongke Li
  • Yufei Hu
چکیده

A novel flow-injection chemiluminescence (FI-CL) method free of CL reagent was developed for the determination of captopril based on its enhancing effect on the CL derived from diperiodatoargentate(III)-sulfuric acid system. Compared with the conventional CL system, the CL system based on trivalent silver was characterized of good selectivity for the absence of CL reagent. The CL mechanism was discussed through CL spectra and UV-vis absorption spectra. The conditions of the FI-CL system were investigated and optimized. Under the optimal conditions, the relative CL intensity was linear with the captopril concentration in the range of 0.3-15.0 μg/mL. The detection limit for captopril was 0.05 μg/mL, and the relative standard deviation (n=11) was 2.0% for 5.0 μg/mL captopril. The proposed method was applied to the analysis of captopril in tablet and human urine with the recoveries of 83.1%-112.5%, and the relative standard deviations of 0.5%-4.4%. The results obtained by the proposed method agreed well with those obtained from HPLC method. The proposed method is fast, convenient, and cost-effective for the determination of captopril in medicine and biological samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Chemiluminescence Determination of Atropine using Luminol-Hemin-H2O2 System

A sensitive and fast chemiluminescence (CL) method has been described for the direct determination of atropine. The method is based on the quenching effect of atropine on the CL signals of the luminol– H2O2 reaction catalyzed by hemin in an alkaline medium. Hemin could strongly enhance the chemiluminescence of the luminol–H2O2 system. The luminophor of the luminol–H2O2–hemin CL system was ident...

متن کامل

Design and Evaluation and Synthesis a Starch-Capped Silver NanoParticles Sensor and Determination trace Sulfacetamide Drug in the Presence Sodium borohydride in Blood and Urine Samples with Kinetic Spectrophotometric Method

A new Kinetic Spectrophotometic method for the Determination of trace amount Sulfacetamide Drug into real samples has been described based with silver nanoparticles starch-capped sensor, by sodium borohydride. The reaction is followed spectrophotometrically by measuring the decrease in the absorbance at 347.5 nm. 1.0×10-2 molL-1 silver nanoparticles starch-capped sensor, 2.0×10-3 mol L-1 sodium...

متن کامل

Application of Differential Kinetic Method Using ANN with a New Synthetic Reagent for Simultaneous Spectrophotometric Determination of Mercury and Palladium

A new selective reagent was used for simultaneous determination of mercury and palladium in real samples with their different kinetic spectrophotometric properties. The method is based on the difference in the rate of the oxidation reaction of the recently synthesized reagent, nitro benzoyl diphenylmethylen phosphorane (N-BDMP), with Hg2+ and Pd2+. The kinetic profiles were monitored and record...

متن کامل

Direct Chemiluminescence Determination of Oxymorphone Using Potassium Permanganate and Polyphosphoric Acid

Abstract A simple and sensitive chemiluminescence (CL) method was developed for direct quantification of oxymorphone, a µ opioid agonist that is approximately 10 times more potent than morphine. In this method potassium permanganate in polyphosphoric acid was used as CL reagent. Using this method, oxymorphone can be determined over the concentration ranges 13.5-337.8 ng mL-1 and 0.34-6.76...

متن کامل

Voltammmetric Determination of Captopril Using Multiwall Carbon Nanotubes Paste Electrode in the Presence of Isoproterenol as a Mediator

The electrocatalytic oxidation of captopril (CAP) was studied by modified carbon nanotubes paste electrode in the presence of isoproterenol (ISPT) using cyclic voltammetry (CV), chronoamperometry and square wave voltammetry (SWV). Also, the values of catalytic rate constant (k), and electron transfer coefficient (α) for CAP were calculated. The mechanism of CA electrochemical behavior at the mo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2017