Silicon and aluminium interactions in haemodialysis patients.

نویسندگان

  • R Parry
  • D Plowman
  • H T Delves
  • N B Roberts
  • J D Birchall
  • J P Bellia
  • A Davenport
  • R Ahmad
  • I Fahal
  • P Altmann
چکیده

BACKGROUND Aluminium toxicity in dialysis patients is well described. Aluminium has a close chemical affinity with silicon. Silicon may have a role in protection against aluminium toxicity. METHODS We measured serum aluminium and silicon levels from haemodialysis patients from four different centres. RESULTS Though no relationship was seen across all centres combined, in one centre there was a reciprocal relationship in patients on home haemodialysis (who did not require reverse osmosis). Median (range) aluminium levels were higher, 2.2 (0.4-9.6) micromol/l when serum silicon was less than 150 micromol/l, and lower, 1.1 (0.2-2.8) micromol/l when serum silicon levels were greater than 150 micromol/l (P = 0.03). CONCLUSIONS In patients treated by haemodialysis without reverse osmosis high serum silicon concentrations were associated with lower serum aluminium concentrations than those with low serum silicon. Further work needs to confirm a preventative role for silicon in the accumulation and subsequent toxicity of aluminium in dialysis patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Varying Silicon Carbide Particulate on the Mechanical Properties of Aluminium Based Alloy Automobile Brake Disc Component

In the current study, effect of varying Silicon Carbide particulate on the mechanical properties of Aluminium based alloy automobile brake disc component was investigated. The result of experimental investigation on mechanical properties of Silicon Carbide particle reinforced Aluminium Matrix was achieved for composite brake disc using universal tensile test machine, Rockwell hardness testing m...

متن کامل

Serum aluminium concentration and aluminium deposits in bone in patients receiving haemodialysis.

Serum aluminium concentrations and biopsy specimens of bone were examined in 56 patients with end stage chronic renal failure receiving maintenance haemodialysis. Deposits of aluminium in bone specimens were often associated with low bone formation with or without osteomalacia. Serum aluminium concentrations of greater than 3.7 mumol/l (10 micrograms/100 ml) indicated a high probability of depo...

متن کامل

Bone aluminium in haemodialysed patients and in rats injected with aluminium chloride: relationship to impaired bone mineralisation.

Iliac bone aluminium was determined by neutron activation analysis in 34 patients with chronic renal failure and in eight control subjects. In 17 patients treated by haemodialysis there was a significant increase in the amount of aluminium (mean +/- SE = 152 +/- 30 ppm bone ash). In eight patients treated by haemodialysis and subsequent renal transplantation, bone aluminium was still significan...

متن کامل

Impact of Clinical Pharmacist-Provided Education on Medication Adherence Behaviour in ESRD Patients on Haemodialysis

      The aim of this research is to assess the impact of clinical pharmacist-provided education on medication adherence in haemodialysis patients. Ninety haemodialysis patients were randomized into two groups. Brief medication questionnaire (BMQ), a tool for screening adherence was administered to both groups at the baseline to assess adherence to antihypertensives, vitamin D analogues, phosph...

متن کامل

Changes in bone histoquantitative parameters and histochemical staining reactions for aluminium in a group of patients with chronic renal failure following a reduction in the aluminium concentration of the haemodialysis fluid.

Bone biopsies from a group of 16 patients in chronic renal failure treated by intermittent haemodialysis were available for histoquantitative and histochemical assessment before and after the introduction of reverse osmosis treatment of the dialysis fluid. This treatment reduced the aluminium concentration of the fluid from 1.15 mg/l to less than 0.06 mg/l. After the changeover there was an inc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association

دوره 13 7  شماره 

صفحات  -

تاریخ انتشار 1998