Use of rapid screening tests in processing urine specimens by conventional culture and the AutoMicrobic system.
نویسندگان
چکیده
Two rapid urine screening tests, the Chemstrip LN (BioDynamics, Indianapolis, Ind.) and the Bac-T-Screen urine screening device (Marion Laboratories, Inc., Kansas City, Mo.), were evaluated as techniques to predict bacteriuria as quantitated by either conventional culture or the AutoMicrobic system (Vitek Systems, Inc., Hazelwood, Mo.). A total of 666 urine specimens were analyzed by both screening tests as well as the AutoMicrobic system and quantitative culture. The sensitivities of both Chemstrip LN and Bac-T-Screen for the detection of low levels of bacteriuria (greater than or equal to 10(3) CFU/ml) were comparable (73.3 and 74.4%, respectively) and were too low to recommend their use as a primary urine screen. Their excellent predictive value of a negative result at the 10(5) CFU/ml level (96 and 97.5%, respectively) makes them potentially useful in predicting urine specimens with less than 10(5) CFU/ml. The use of either of these tests in combination with the AutoMicrobic system markedly decreased the time required to classify urine specimens. Their low cost relative to the AutoMicrobic system urine card makes the use of either test cost effective as a screen for the AutoMicrobic system.
منابع مشابه
Cost analysis of the Auto Microbic system urine identification card.
The AutoMicrobic system (Vitek Systems, Inc., Hazelwood, Mo.) is a fully automated, computerized instrument. One of the most thoroughly studied aspects of the system is its ability to identify and quantify of nine most common urinary tract pathogens. The major advantages of the AutoMicrobic system are that the results of urine cultures are available in a fraction of the time required by convent...
متن کاملRapid method for identification and susceptibility testing of Escherichia coli bacteriuria.
This report describes a rapid method for the identification and susceptibility testing of Escherichia coli bacteriuria by use of the Autobac urine screen (AUS), a 5-h indole test, and the AutoMicrobic system E. coli Susceptibility Card (AMS-ECSC). All specimens that were AUS negative at 3 and 5 h were reported as negative. All specimens that were AUS positive at 3 or 5 h were removed from the r...
متن کاملAutomated microbiological detection/identification system.
An automated, computerized system, the AutoMicrobic System, has been developed for the detection, enumeration, and identification of bacteria and yeasts in clinical specimens. The biological basis for the system resides in lyophilized, highly selective and specific media enclosed in wells of a disposable plastic cuvette; introduction of a suitable specimen rehydrates and inoculates the media in...
متن کاملClinical comparison of the AutoMicrobic system gram-positive identification card, API Staph-Ident, and conventional methods in the identification of coagulase-negative Staphylococcus spp.
In an effort to rapidly identify coagulase-negative staphylococci (CNS), a clinical comparison was conducted with the AutoMicrobic system Gram-Positive Identification Card (GPI) (Vitek Systems, Inc.), the API Staph-Ident (Analytab Products), and the conventional methods of W. E. Kloos and K. H. Schleifer (W. E. Kloos and K. H. Schleifer, J. Clin. Microbiol. 1:82-88, 1975). CNS isolates tested i...
متن کاملCulture of Urine Specimens by Use of chromID CPS Elite Medium Can Expedite Escherichia coli Identification and Reduce Hands-On Time in the Clinical Laboratory.
Urine is one of the most common specimen types submitted to the clinical microbiology laboratory; the use of chromogenic agar is one method by which the laboratory might expedite culture results and reduce hands-on time and materials required for urine culture analysis. The objective of our study was to compare chromID CPS Elite (bioMérieux), a chromogenic medium, to conventional primary cultur...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of clinical microbiology
دوره 21 5 شماره
صفحات -
تاریخ انتشار 1985