Optimization of CCGT power plant and performance analysis using MATLAB/Simulink with actual operational data

نویسندگان

  • Naimul Hasan
  • Jitendra Nath Rai
  • Bharat Bhushan Arora
چکیده

In the Modern scenario, the naturally available resources for power generation are being depleted at an alarming rate; firstly due to wastage of power at consumer end, secondly due to inefficiency of various power system components. A Combined Cycle Gas Turbine (CCGT) integrates two cycles- Brayton cycle (Gas Turbine) and Rankine cycle (Steam Turbine) with the objective of increasing overall plant efficiency. This is accomplished by utilising the exhaust of Gas Turbine through a waste-heat recovery boiler to run a Steam Turbine. The efficiency of a gas turbine which ranges from 28% to 33% can hence be raised to about 60% by recovering some of the low grade thermal energy from the exhaust gas for steam turbine process. This paper is a study for the modelling of CCGT and comparing it with actual operational data. The performance model for CCGT plant was developed in MATLAB/Simulink.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance Analysis of CCGT Power Plant using MATLAB/Simulink Based Simulation

Combined Cycle Gas Turbine (CCGT) integrates two cyclesBrayton cycle (Gas Turbine) and Rankine cycle (Steam Turbine) with the objective of increasing overall plant efficiency. In modern gas turbine the temperature of the exhaust gases is in the range of 500 oC to 550 oC. Modern steam power plants have steam temperature in the range of 500 oC to 630 oC. Hence gas turbine exhaust can be utilized ...

متن کامل

Parameter Estimation and Dynamic Simulation Of Gas Turbine Model In Combined Cycle Power Plants Based On Actual Operational Data

Gas turbines are very important nowadays for electric power generation specially that used in the Combined Cycle Power Plants (CCPPs). For this electric power generation, the dynamics of the gas turbine and parameters estimation are very essential. In this article, a simple procedure is used for estimating the parameters of Rowen’s model for HDGTs in dynamic studies for analysis purposes. The p...

متن کامل

Thermodynamic Assessment and Parametric Study of a Supercritical Thermal Power Plant

A thermodynamic analysis of an operational 315 MW supercritical steam power plant (SPP) using the actual data is performed to assess the plant performance and identify the sites of energy losses and exergy destructions in each component of the plant. Various performance parameters such as component energy and exergy efficiencies, energy loss rate, exergy destruction rate, improvement potential ...

متن کامل

A MATLAB / SIMULINK BASED FAULT ANALYSIS OF SMALL HYDROPOWER PLANT

ABSTRACTRenewable Energy Sources (RES) are well – defined as energy sources, that are in abundance within the natural surroundings and are much inexhaustible. In addition, hydroelectricity (HE) is a vital part of world renewable energy supply and hydropower remains a bulk source of electricity generation because of its environmental friendliness in nature. Modeling is the analysis of the ...

متن کامل

Comparison Of Asymmetrical Cascaded Multilevel Inverter Control Techniques

This paper presents asymmetrical cascaded multilevel inverter (ACMLI) approach for high voltage and high power output applications. It is based on the cascade connection of the H-bridge inverter cells. Now ever by the supplies which are in GP with different ratios like 2,3,etc. The proposed configuration is shown for 27 level inverters with symmetrical step control, optimization angle control a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2014