A Technique for Force Calibration MEMS Traceable to NIST Standards
نویسندگان
چکیده
Characterizing the mechanical properties of materials and biological systems at the nanoscale requires accurate measurement of forces on the order of 10’s of μN and less. Many times custom fabricated MEMS actuators and load cells are employed to apply these forces. Force response of these devices may be very different from their anticipated response due to fabrication induced effects. This makes it necessary to develop a method for their calibration that can be traced back to the National Institute of Standards and Technology (NIST). Due to the scale of the measurements and size of the instrumentation, calibration of nanoscale devices presents a new challenge in metrology. We have developed a novel method to calibrate a MEMS actuator with force resolution on the order of 1 μN using the tried-and-true deadweight method, but on the microscale. Calibrations are performed by suspending weights (traceably weighed sapphire spheres) from the MEMS device using the surface tension of water. The displacement was measured by measuring changes in capacitance and verified using a co-fabricated vernier. Measurements have been made using this method. Comparisons between our traceably calibrated force–displacement curves to a non-linear theoretical prediction, errors as great as 29% are revealed.
منابع مشابه
Uncertainty in NIST Force Measurements
This paper focuses upon the uncertainty of force calibration measurements at the National Institute of Standards and Technology (NIST). The uncertainty of the realization of force for the national deadweight force standards at NIST is discussed, as well as the uncertainties associated with NIST's voltage-ratio measuring instruments and with the characteristics of transducers being calibrated. T...
متن کاملDevelopment of a traceable calibration methodology for solid (68)Ge/(68)Ga sources used as a calibration surrogate for (18)F in radionuclide activity calibrators.
UNLABELLED We have developed a methodology for calibrating (68)Ge radioactivity content in a commercially available calibration source for activity calibrators in a way that is traceable to the national standard. Additionally, the source was cross-calibrated for equivalent (18)F content by direct comparison with the national standard for (18)F in the same geometry. METHODS Sources containing ...
متن کاملBest Practice Guidelines for Pre-Launch Characterization and Calibration of Instruments for Passive Optical Remote Sensing1
The pre-launch characterization and calibration of remote sensing instruments should be planned and carried out in conjunction with their design and development to meet the mission requirements. The onboard calibrators such as blackbodies and the sensors such as spectral radiometers should be characterized and calibrated using SI traceable standards. In the case of earth remote sensing, this al...
متن کاملStandardization of 68Ge/68Ga Using Three Liquid Scintillation Counting Based Methods
A solution containing (68)Ge in equilibrium with its daughter, (68)Ga, has been standardized for the first time at the National Institute of Standards and Technology (NIST) using 3 liquid scintillation-based techniques: live-timed 4πβ -γ anticoincidence (LTAC) counting, the Triple-to-Double Coincidence Ratio (TDCR) method, and (3)H-standard efficiency tracing with the CIEMAT(1)/NIST (CNET) meth...
متن کاملLandsat-8 Operational Land Imager Radiometric Calibration and Stability
The Landsat-8 Operational Land Imager (OLI) was radiometrically calibrated prior to launch in terms of spectral radiance, using an integrating sphere source traceable to National Institute of Standards and Technology (NIST) standards of spectral irradiance. It was calibrated on-orbit in terms of reflectance using diffusers characterized prior to launch using NIST traceable standards. The radian...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -