Reduction of fast spin echo cusp artifact using a slice-tilting gradient.

نویسندگان

  • Novena Rangwala
  • Xiaohong Joe Zhou
چکیده

A "featherlike" artifact, termed a cusp artifact, is sometimes seen along the phase-encoding direction in sagittal or coronal fast spin echo images. This artifact arises from the spins, at a location distant from the magnet isocenter, that are excited and aliased to the field of view because their precession frequency is similar to those at the isocenter. Such a situation is created due to a combination of excessive gradient nonlinearity and rapid change of the main magnetic field near the edge of the magnet where the artifact-producing spins are located. A novel technique is proposed to reduce this artifact, in which a fast spin echo pulse sequence is modified to slightly tilt the slice selected by the radiofrequency excitation pulse away from the slice selected by the radiofrequency refocusing pulses. At the edge of the field of view, the incomplete overlap between the slices selected by the excitation and refocusing pulses effectively reduces the signals from the artifact-prone region. In contrast, the slices overlap substantially within the field of view so that the signals are largely retained. This slice-tilting technique has been implemented on two commercial MRI scanners operating at 3.0 T and 1.5 T, respectively, and evaluated on phantoms and human spine and extremities using clinical protocols. Both phantom and human results showed that the technique decreased the strength of the cusp artifact by at least 65% and substantially limited the spatial extent of the artifact. This technique, which can be further enhanced by a simple postprocessing step, offers significant advantages over a number of other techniques for reducing the fast spin echo cusp artifact. It can be implemented on virtually any scanner without hardware modification, complicated calibration, sophisticated image reconstruction, or patient-handling alteration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reduction of FSE Cusp Artifact Using Slice Tilting

Introduction With specific combinations of B0-field, B1-field, and gradient field, peripheral signals outside the prescribed field of view (FOV) can fold back onto the image, resulting in a bright spot, a series of spots, a band, or a “feather-like” artifact along the phase encoding direction. In a fast spin echo (FSE) image, this type of artifact has been termed as cusp artifact [1,2], annefac...

متن کامل

Material-Dependent Implant Artifact Reduction Using SEMAC-VAT and MAVRIC: A Prospective MRI Phantom Study.

OBJECTIVE The aim of this study was to compare the degree of artifact reduction in magnetic resonance imaging achieved with slice encoding for metal artifact correction (SEMAC) in combination with view angle tilting (VAT) and multiacquisition variable resonance image combination (MAVRIC) for standard contrast weightings and different metallic materials. METHODS Four identically shaped rods ma...

متن کامل

Comparison of optimized fast spin echo (FSE) magnetic resonance (MR) imaging to view angle tilt (VAT) FSE in the reduction of metallic susceptibility artifact surrounding arthroplasty

Introduction / Background: MR imaging of arthroplasty has traditionally been limited by the presence of artifact generated by the metallic components, which comparatively demonstrate higher magnetic susceptibility than the adjacent bone and soft tissue (1-3). The sources of these artifacts include induction of radiofrequency eddy currents in the metal, warping of the slice during slice selectio...

متن کامل

Accelerated slice encoding for metal artifact correction.

PURPOSE To demonstrate accelerated imaging with both artifact reduction and different contrast mechanisms near metallic implants. MATERIALS AND METHODS Slice-encoding for metal artifact correction (SEMAC) is a modified spin echo sequence that uses view-angle tilting and slice-direction phase encoding to correct both in-plane and through-plane artifacts. Standard spin echo trains and short-TI ...

متن کامل

اندازه گیری غیریکنواختی امواج رادیوئی در ام آر آی

Introduction: Non-uniformity is one of the most important parameters affecting MRI images which can lead to harmful effects in the diagnosis and analysis of qualitative and quantitative methods. The present study introduced a method for measuring RF non-homogeneity in MRI systems. Methods and Materials: To verify the uniformity of B0 and B1 fields, a cylindrical phantom with a diameter of 24 c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 64 1  شماره 

صفحات  -

تاریخ انتشار 2010