Comparison of plasma virus loads among individuals infected with hepatitis C virus (HCV) genotypes 1, 2, and 3 by quantiplex HCV RNA assay versions 1 and 2, Roche Monitor assay, and an in-house limiting dilution method.
نویسندگان
چکیده
The accuracy of different methods for the quantitation of hepatitis C virus in plasma was measured with samples from individuals infected with different genotypes and by using RNA transcripts of predetermined concentrations. Highly reproducible results were observed upon repeat testing of samples by both the original version of the Chiron branched-DNA (bDNA) assay (Quantiplex RNA assay; bDNA-1) and the currently available version (Quantiplex HCV RNA 2.0 assay; bDNA-2). A greater variability was observed in the Roche Monitor assay (correlation coefficient of 0.537, compared with 0.942 and 0.964 for the bDNA-1 and bDNA-2 assays, respectively). Significant differences in the efficiency of detection of genotypes 1, 2, and 3 were observed for the bDNA-1 and Roche Monitor assays, whereas the bDNA-2 assay and nested PCR at limiting dilution were able to quantify genotypes with equal sensitivity. By quantifying RNA transcripts of different genotypes, the sensitivities of the Roche Monitor assay for sequences of the type 2 and type 3 transcripts were estimated to be 11 and 8% of those achieved for genotype 1. When correction factors based upon these results and those from quantitation of circulating viral RNA sequences in samples from blood donors were used, the genotype-specific differences in virus load in samples from blood donors were no longer observed, consistent with previous studies with corrected values from the bDNA-1 assay. These results suggest that many of the previous studies evaluating the effect of genotype and virus load on the response to interferon using methods such as the Roche Monitor assay and other competitive PCR methods require reinterpretation. Differences in efficiency of quantitation should be taken into account in future investigations of the relationship between genotype and virus load.
منابع مشابه
Genotype dependence of hepatitis C virus load measurement in commercially available quantitative assays.
Standardization and genotype independence of methods used to quantify hepatitis C virus (HCV) RNA in clinical specimens are necessary for accurate assessment of the role of HCV quantitation as a prognostic marker for HCV infection and monitoring of the response to antiviral treatment. Commercially available methods used to measure HCV loads include PCR-based (Roche Monitor) and hybridization-ba...
متن کاملInvestigation of Human Leukocyte Antigen (HLA) Class I and II Alleles and Hepatitis C Virus (HCV) Genotypes in Patients Infected with HCV
Hepatitis C virus (HCV) is a major public health problem with more than 130-180 million people infected worldwide. Several studies in different populations have reported the association of human leukocyte antigen (HLA) genotypes, and HCV viral load, and genotypes. The aim of this study was to investigate a possible association between HLA class I and II alleles in HCV-infected patients and heal...
متن کاملDistribution of Hepatitis C virus genotypes in Yazd, Central Province of Iran: increasing the mixed genotypes
Background and Aims: Different hepatitis C virus (HCV) genotypes have characteristic geographical distribution. Identification of HCV genotype is an important factor in the progression, clinical outcome and therapy of HCV infection. The aim of this study was to determine the prevalence of HCV genotypes among HCV-RNA positive patients in Yazd, Iran. Materials and Methods: In this cross-sectiona...
متن کاملComparison of two quantitative hepatitis C virus reverse transcriptase PCR assays.
A quantitative hepatitis C virus reverse transcriptase PCR (HCV RT-PCR) assay established in our laboratory was compared with the Roche Amplicor HCV Monitor test kit for agreement of test results and intra-assay variability. Both assays rely on reverse transcription and amplification of extracted RNA from patients' sera together with an internal RNA standard derived from the 5'-noncoding region...
متن کاملPerformance of the New Bayer VERSANT HCV RNA 3.0 assay for quantitation of hepatitis C virus RNA in plasma and serum: conversion to international units and comparison with the Roche COBAS Amplicor HCV Monitor, Version 2.0, assay.
We have evaluated the VERSANT HCV RNA 3.0. Assay (HCV 3.0 bDNA assay) (Bayer Diagnostics, Berkeley, Calif.), which is an improved signal amplification procedure for the HCV 2.0 bDNA assay for the quantitation of hepatitis C virus (HCV) RNA in serum or plasma of HCV-infected individuals. The HCV 3.0 bDNA assay has a linear dynamic range of 2.5 x 10(3) to 4.0 x 10(7) HCV RNA copies per ml (c/ml)....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of clinical microbiology
دوره 35 1 شماره
صفحات -
تاریخ انتشار 1997