Removing Systematic Errors from Rotating Shadowband Pyranometer Data

نویسنده

  • Frank Vignola
چکیده

Rotating Shadowband Pyranometers (RSPs) have been deployed to measure global, beam, and diffuse irradiance because they do not require manual adjustment of trackers. However, a RSP requires the use of solar cell based pyranometers which underestimate diffuse irradiance by 20-30% under clear sky conditions. Algorithms were derived to address many of the systematic errors in solar cell based measurements, and these algorithms were incorporated into a new series of RSP instruments. This is an analysis of how similar algorithms can be used to remove some of the systematic errors associated with the data from the original RSPs and an evaluation of the uncertainties and remaining errors in the corrected RSP data.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Solar Cell Based Pyranometers: Evaluation of the Diffuse Response

The responsivity to diffuse radiation of a solar cell based pyranometer is studied. Diffuse measurements are made using a shade disk for a LiCor Pyranometer and an Eppley PSP pyranometer mounted side by side on an automatic tracker. The difference in the diffuse responsivity varies by 30 to 40% between cloudy conditions and clear skies. This difference is attributed to the spectral dependence o...

متن کامل

Calibration Methods for Silicon Photodiode Pyranometers used in Rotating Shadowband Radiometers

Silicon photodiode pyranometers have been studied extensively for application in solar energy resource assessment instruments. An example is the LI-COR, Inc. 200SZ detector that is used in rotating shadowband radiometers. While excellent results have been achieved LI-COR, Inc. calibration methods are not fully disclosed and LI-COR’s stated +/5% accuracy is less than desirable. This research aim...

متن کامل

Shortwave Radiometry and Analysis at the Southern Great Plains (SGP) Site

Here we report the results of three parallel efforts: the recal0.3%. Likewise, Joe Michalsky went to the SGP site with a ibration and reanalysis of pyrano-metric data from Southern recently calibrated Eppley Normal Incidence Pyrheliometer Great Plains (SGP) to improve its accuracy, use of the (NIP) and an Eppley Precision Spectral Pyranometer (PSP). multifilter rotating shadowband radiometer (M...

متن کامل

Retrieval of Aerosol Optical Depth, Aerosol Size Distribution Parameters, Ozone and Nitrogen Dioxide Column Amounts from Multifilter Rotating Shadowband Radiometer Data

The MultiFilter Rotating Shadowband Radiometer (MFRSR) (Harrison and Michalsky 1994a, 1994b) measures atmospheric column extinction of the direct solar beam and the diffuse radiation intensity at six wavelengths. Located at the National Aeronautics and Space Administration's Goddard Institute for Space Studies in New York City, the instrument has six spectral channels at 415, 501, 616, 672, 870...

متن کامل

Rotating Scans for Systematic Error Removal

Optical triangulation laser scanners produce errors at surface discontinuities and sharp features. These systematic errors are anisotropic. We examine the causes of these errors theoretically, and we study the correlation of systematic error with edge size and orientation experimentally. We then present a novel processing method for removing systematic errors, by combining scans taken at severa...