[Percutaneous extraction of pacemaker and defibrillator leads].

نویسندگان

  • Tomasa Centella
  • Enrique Oliva
  • Ignacio García-Andrade
  • Pilar Martín-Dávila
  • Javier Cobo
  • José L Moya
  • Antonio Hernández-Madrid
  • Antonio Epeldegui
چکیده

INTRODUCTION AND OBJECTIVES There is an increasing need for endocardial pacing and defibrillators leads to be removed. However, the procedure can be complex and it is not risk-free. We reviewed our experience between April 1989 and June 2006 with the percutaneous extraction of leads. METHODS In total, 314 electrodes were extracted from 187 patients. The leads had been implanted over an average period of 69.16 months (range 0.11-234.6 months, median 60.25 months). Some 115 were atrial leads, 196 were ventricular, and three were in the coronary veins; of these, 78 had been abandoned in the vascular bed. RESULTS Indications for removal were infection (26.1%), dysfunction (22.9%), erosion (25%), endocarditis (20.7%), and bacteremia (2.7%). Overall, 58.8% of patients were referred from other departments. In 96.8%, the electrodes were completely removed. Simple traction was used in 23.4%, and countertraction techniques (with and without radiofrequency current support) were used in 60.7%. For abandoned leads, a biopsy clamp was used in combination with countertraction (4.3%) or a femoral approach with a snare (10.1%). A sternotomy was required in three of the 10 patients with remaining electrode fragments. The complication rate was 4.6% (with major complications in 2.5%). Complications were associated with age < 60 years (odds ratio [OR]=5.38, 95% confidence interval [CI] 1.07-27.23), the presence of endocarditis (OR=4.97: 95%CI, 1.04-23.70), and right side implantation (OR=17.09; 95% CI, 2.15-135.70). CONCLUSIONS In the majority of cases, pacing and defibrillator leads can be removed without difficulty using modern extraction techniques. However, because there is a risk of complications during extraction, even though it is low, the procedure should be carried out in specialized centers with surgical facilities.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Percutaneous Extraction of Transvenous Permanent Pacemaker/Defibrillator Leads

BACKGROUND Widespread use of cardiovascular implantable electronic devices has inevitably increased the need for lead revision/replacement. We report our experience in percutaneous extraction of transvenous permanent pacemaker/defibrillator leads. METHODS Thirty-six patients admitted to our centre from September 2005 through October 2012 for percutaneous lead extraction were included. Lead re...

متن کامل

Successful percutaneous extraction of pacemaker leads with a novel (VascoExtor) pacing lead removal system.

A new pacing lead extraction system (VascoExtor, VascoMed, Germany) with a universally applicable locking stylet was used over a period of 12 months to extract 25 permanent pacemaker leads (mean implantation time 3.9 +/- 3.8 years) in 16 patients who had pacemaker infection (n = 13), lead dysfunction (n = 2), or before an automatic defibrillator implant (n = 1). With use of this system, we were...

متن کامل

Is correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...

متن کامل

Pacemaker lead endocarditis with hiccups (Kalayci)

Background: Lead-related infections that might develop after pacemaker implantation associated with high mortality and morbidity rates are challenging to manage and pose high-cost. Patients with lead-related infections usually present with fever, chills and fatigue and the treatment can be challenging unless the implant system is extracted. Case presentation: A 66-year old male patient who und...

متن کامل

An Implantable Left Atrial Pressure Sensor Lead Designed for Percutaneous Extraction Using Standard Techniques

BACKGROUND An implantable left atrial pressure (LAP) monitoring system for guiding the management of patients with advanced heart failure has the potential to require extraction, particularly in the setting of infection. The LAP sensor lead was designed to be suitable for ease of percutaneous extraction using standard techniques for extracting pacemaker and defibrillator leads. The clinical exp...

متن کامل

Laser assisted extraction of pacemaker and implantable defibrillator leads.

OBJECTIVE To analyze the results of laser-assisted extraction of permanent pacemaker and defibrillator leads. METHODS We operated upon 36 patients, whose mean age was 54.2 years, and extracted 56 leads. The reasons for extracting the leads were as follows: infection in 19 patients, elective replacement in 13, and other causes in 4 patients. The mean time of catheter placement was 7.5+/-5.5 ye...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Revista espanola de cardiologia

دوره 60 6  شماره 

صفحات  -

تاریخ انتشار 2007