A parallel computing framework for motion-compensated reconstruction based on the motion point-spread function

نویسندگان

  • F. Odille
  • P. G. Batchelor
  • C. Prieto
  • T. Schaeffter
  • D. Atkinson
چکیده

INTRODUCTION Generalized reconstruction frameworks allowing correction of nonrigid displacements during MR acquisition (inter-view motion) have been proposed recently [1,2]. Their main drawback is their computational complexity which makes them currently impractical for clinical use. Based on the properties of the point-spread function (PSF) describing the occurrence of motion-artifacts, we propose a method for splitting the reconstruction process into several reconstruction tasks of smaller size. This allows easier and more efficient implementation of these algorithms on a parallel architecture such as a cluster of workstation, both in terms of reconstruction time and memory requirement.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of Various Image Reconstruction Methods on Joint Compensation of Respiratory Motion and Partial Volume Effects in Whole-Body 18F-FDG PET/CT Imaging: Patients with Non-Small Cell Lung Cancer

Background: The present study aims to assess the impact of various image reconstruction methods in 18F-FDG PET/CT imaging on the quantification performance of the proposed technique for joint compensation of respiratory motion and partial volume effects (PVEs) in patients with non-small cell lung cancer. Materials and Methods: An image-based deconvolution technique was proposed, incorporating w...

متن کامل

Motion-Compensated Cone Beam CT Using a Conjugate Gradient Least Squares Algorithm and EIT Imaging Motion Data

Cone Beam Computed Tomography (CBCT) is an imaging modality that has been used in image-guided radiation therapy (IGRT). For applications such as lung radiation therapy, CBCT images are greatly affected by the motion artefacts. This is mainly due to low temporal resolution of CBCT. Recently, a dual modality of Electrical Impedance Tomography (EIT) and CBCT has been proposed, in which the high t...

متن کامل

Quantitative PET image reconstruction employing nested expectation-maximization deconvolution for motion compensation

Bulk body motion may randomly occur during PET acquisitions introducing blurring, attenuation-emission mismatches and, in dynamic PET, discontinuities in the measured time activity curves between consecutive frames. Meanwhile, dynamic PET scans are longer, thus increasing the probability of bulk motion. In this study, we propose a streamlined 3D PET motion-compensated image reconstruction (3D-M...

متن کامل

Trajectory Optimization of Cable Parallel Manipulators in Point-to-Point Motion

Planning robot trajectory is a complex task that plays a significant role in design and application of robots in task space. The problem is formulated as a trajectory optimization problem which is fundamentally a constrained nonlinear optimization problem. Open-loop optimal control method is proposed as an approach for trajectory optimization of cable parallel manipulator for a given two-end-po...

متن کامل

Assessment of simulated patient motion and its effect on myocardial perfusion SPECT using two reconstruction methods (Filtered Backprojection;FBP and Iterative method) [Persian]

Introduction: Motion of the patient during myocardial perfusion SPECT could potentially results in false perfusion defects. The effect of different reconstruction methods on these artifacts is not studied. Clarification of the relation between the extent, severity and duration of motion with the resultant artifacts may be helpful in designing special soft wares for motion correction. This...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009