Highly accelerated Point-Spread Function mapping based on Finite Rate of Innovation for EPI distortion correction
نویسندگان
چکیده
Institute of Biophysics and Biomedical Engineering, Faculty of Sciences, University of Lisbon, Lisbon, Portugal Hybrid MR-PET scans enable acquisition of both types of images within a session. Despite consistent subject positioning, image alignment can still be challenging. Functional MR images rely on echo-planar imaging (EPI) and present geometric distortions due to static B0 field inhomogeneities. Direct B0 [1] and Point Spread Function (PSF) mapping [2] (Figure 1) have been proposed for distortion correction. The PSF method is more robust [3], but acquisition times are long even with previous acceleration approaches [4-7]. We used the Finite Rate of Innovation (FRI) framework [8,9] to detect the PSF peak position to sub-pixel precision using as few ks samples as possible. Images were acquired on a 3.0T Philips Achieva: 2.5×2.5×4.0 mm, matrix 96×95, 95 ks steps with under-sampling retrospectively performed. PSF peak position was estimated using both the fully-sampled (zero-filled by a factor of 1000) and highly-undersampled data. To determine the PSF peak location, pattern matching was performed. The signal measured at each spatial location was compared to a predicted signal pattern accounting for the ks sampling scheme and the search progressively refined up to the intended precision. EPI images were undistorted as in [10]. Figure 2 shows example PSF peak shift maps (relative to expected undistorted positions). Figure 3A shows the original EPI slice matching Figure 2, and Figures 3B-E show the corrected images using each displacement map. Comparison with the GE image (Figure 3F) confirms accurate geometrical corrections. Using the proposed approach the position of the PSF peak can be estimated from a very small number of samples. In the future distortion map estimation could easily be incorporated into standard preparation phases. Making distortion correction of EPI images more practical would facilitate combining functional PET and MR information as well as structural connectivity information from diffusion-weighted MR images. Nunes and Hajnal EJNMMI Physics 2014, 1(Suppl 1):A45 http://www.ejnmmiphys.com/content/1/S1/A45
منابع مشابه
Accelerated Point Spread Function Mapping Using Compressed Sensing for EPI Geometric Distortion Correction
Introduction: Single-shot echo-planar imaging (EPI) is a fast technique allowing the acquisition of an image following a single RF excitation. The high temporal resolution of EPI makes it the method of choice for applications such as fMRI or diffusion tensor imaging. However, EPI is prone to geometric and intensity distortions in the presence of magnetic field inhomogeneities. Several correctio...
متن کاملImage distortion correction in EPI: comparison of field mapping with point spread function mapping.
Echo-planar imaging (EPI) can provide rapid imaging by acquiring a complete k-space data set in a single acquisition. However, this approach suffers from distortion effects in geometry and intensity, resulting in poor image quality. The distortions, caused primarily by field inhomogeneities, lead to intensity loss and voxel shifts, the latter of which are particularly severe in the phase-encode...
متن کاملPoint spread function mapping for distortion correction of spinal cord diffusion weighted MRI
Introduction Diffusion Weighted Magnetic Resonance Imaging (DWMRI) is a promising method to assess axonal integrity in the spinal cord in vivo [1]. However, the fast imaging sequences required for in vivo DWMRI are sensitive to B0-field inhomogeneities caused by susceptibility differences around vertebral structures and lungs. Those inhomogeneities cause voxel shift that corrupt the anatomical ...
متن کاملDistortion Correction in EPI Using an Extended PSF Method with a Reversed Phase Gradient Approach
In echo-planar imaging (EPI), such as commonly used for functional MRI (fMRI) and diffusion-tensor imaging (DTI), compressed distortion is a more difficult challenge than local stretching as spatial information can be lost in strongly compressed areas. In addition, the effects are more severe at ultra-high field (UHF) such as 7T due to increased field inhomogeneity. To resolve this problem, two...
متن کاملCorrection of B0 susceptibility induced distortion in diffusion-weighted images using large-deformation diffeomorphic metric mapping.
Geometric distortion caused by B0 inhomogeneity is one of the most important problems for diffusion-weighted images (DWI) using single-shot, echo planar imaging (SS-EPI). In this study, large-deformation, diffeomorphic metric mapping (LDDMM) algorithm has been tested for the correction of geometric distortion in diffusion tensor images (DTI). Based on data from nine normal subjects, the amount ...