The value of the coefficient of variation in assessing repeat variation in ECG measurements.

نویسندگان

  • S C McLaughlin
  • T C Aitchison
  • P W Macfarlane
چکیده

AIMS The coefficient of variation is a popular measure for describing the amount of repeat variability present in ECG measurements from recording to recording. However, it can be misleading. The aim of the present study was to assess repeat variation (reclassification) in computer measured ECG criteria, i.e. positive to negative or vice versa, and compare this with the coefficient of variability. METHODS AND RESULTS Two ECGs were obtained from each of 295 patients, one day apart, and separately from a further 364 patients, several minutes apart. All patients were considered to be in a stable condition. Estimates of the coefficients of variation were obtained for a number of ECG parameters used in the diagnosis of left ventricular hypertrophy. Corresponding reclassification rates of relevant ECG criteria were also calculated. Large coefficients of variation were observed in voltage parameters, e.g. R in V5 (20% for day-to-day recordings and 6% for minute-to-minute recordings) while the corresponding reclassification rates were 8% and 0% respectively. The repeat variation in the diagnosis of left ventricular hypertrophy was up to 5% for day-to-day recordings and up to 3% for minute-to-minute recordings based on several different criteria. CONCLUSION A large coefficient of variation in a particular variable does not necessarily correspond to a high reclassification rate. A better measure of the impact of ECG variability for a particular measurement is obtained from its reclassification rate. In turn, this may have a minimal effect on the overall diagnosis of a particular abnormality.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Independence of color intensity variation in red flesh apples from the number of repeat units in promoter region of the MdMYB10 gene as an allele to MdMYB1 and MdMYBA

MdMYB10 gene expression results in accumulation of anthocyanin in many tissues including flesh of applefruit. The MdMYB1 and MdMYBA genes are close homologues to MdMYB10 gene and both are responsiblefor red color phenotype in apple fruit skin. In the current study, an apple genome sequence draft analysisindicated that these three genes are located in a unique contig. Further a...

متن کامل

Genetic Variation of Informative Short Tandem Repeat (STR) Loci in an Iranian Population

In the present study, genotyping of six short tandem repeat (STR) loci including CSF1PO, D16S539, F13A01, F13B, LPL and HPRTB was performed on genomic DNA from 127 unrelated individuals from the Iranian province of Isfahan. The results indicated that the allele and genotype distributions were in accordance with Hardy-Weinberg expectations. The observed heterozygosity (Ho), expected heterozygosi...

متن کامل

Investigation of genetic variation in Haloxylon salicornicum (Moq.) Bunge ex Boiss in Different habitats by ISSR Markers (Case study: Yazd)

Haloxylon salicornicum (Moq.) Bunge ex Boiss is a shrub that grows in large parts of the central regions of Iran. Due to the high adaptability of this species to the severe environmental conditions and its importance in the stabilization of sand dunes, Dust control and medicinal functions recognition of its genetic diversity and the selection of superior genotypes is very important. A set of ...

متن کامل

Effects Of Frequency Variation At Inlet Flow On The Vortex Shedding Frequency Behind A Circular Cylinder

In many applications the flow that past bluff bodies has frequency nature (oscillated) and it is not uniform. This kind of flow has effects on the formation of vortex shedding behind bluff bodies. In this paper the flow around a circular cylinder was numerically simulated. The effects of frequency variation at inlet flow on the vortex shedding frequency were investigated. The transient Two-Dime...

متن کامل

USE OF MYELOPEROXIDASE INDEX AS A SUITABLE TOOL TO MONITOR RESPONSE TO THERAPY IN PATIENTS WITH MEGALOBLASTIC ANEMIA

Repeated bone marrow examination was found to be of value in assessing response to treatment in megaloblastic anemia. The objective of this study was monitoring the response of megaloblastics to treatment, concerning the location of neutrophilic myeloperoxidase and myeloperoxidase index (MPXI) and their variation in megaloblastic erythroid progeny. It is possible to follow up megaloblastic ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • European heart journal

دوره 19 2  شماره 

صفحات  -

تاریخ انتشار 1998