Isolated acetabular revision with use of the Harris-Galante Cementless Component. Study with intermediate-term follow-up.

نویسندگان

  • Amir A Jamali
  • Danton S Dungy
  • Arthur Mark
  • Steven Schule
  • William H Harris
چکیده

BACKGROUND Isolated revision of an acetabular total hip component is associated with special problems related to the retention of the femoral component. We reviewed the intermediate-term results of a series of such operations with use of the Harris-Galante Porous acetabular component. METHODS We retrospectively studied the results of ninety-five isolated acetabular revisions, specifically focusing on sixty-three that had been followed for a minimum of sixty months (average, 130 months). Evaluation measures included the Harris hip score, radiographic analysis, complications, and prosthetic survival. Follow-up information was obtained with self-administered questionnaires, telephone contact, and/or clinical examination. The effects of a femoral component with a modular neck-head junction and of trochanteric osteotomy on the dislocation rate were evaluated. RESULTS Nine shells were rerevised: four because of recurrent dislocation, four because of aseptic loosening, and one because of dissociation of the liner. The survival rate with rerevision of the shell as the end point was 90.5% at 120 months. Pelvic osteolysis occurred in 4% of the cases. The dislocation rate for the sixty-three hips was 8%. When femoral component modularity was accounted for, the analysis of the dislocations revealed a significantly higher dislocation rate for the hips without a trochanteric osteotomy (p = 0.04). Eight arthroplasties were complicated by nerve palsies, seven of which resolved fully or nearly so. CONCLUSIONS Isolated acetabular revision with use of the Harris-Galante Porous acetabular component was associated with a low rate of loosening, lysis, and rerevision of the shell at the time of intermediate-term follow-up. However, there was a high rate of complications, including trochanteric nonunion, dislocation, and nerve palsy. The performance of a trochanteric osteotomy was associated with a decreased rate of dislocation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs

Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations.Methods: 52 primary cementless total hip arthroplasty in...

متن کامل

Harris Galante cementless acetabular replacement in avascular necrosis.

We describe the results of 76 total arthroplasties of the hip for stage-III or stage-IV avascular necrosis of the femoral head. Harris Galante Porous cups were used in 63 patients between 1986 and 1994 and followed prospectively. We reviewed 70 hips with a follow-up of more than five years (mean 7.6). At the latest review the mean Harris Hip Score had improved from a preoperative value of 29 +/...

متن کامل

Revision of the acetabulum with a contemporary cementless component.

We evaluated the performance of a contemporary cementless acetabular component at a minimum of 5 years postoperatively. One hundred eighty-seven consecutive acetabular component revisions were performed using a hemispherical porous-coated component. Patients were followed prospectively with radiographs and Harris hip scores. Twenty patients died, leaving 158 patients (166 hips) available for fo...

متن کامل

Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs

BACKGROUND Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations. METHODS 52 primary cementless total hip arthroplasty i...

متن کامل

The Harris-Galante porous-coated, hemispherical, polyethylene-lined acetabular component in patients under 50 years of age: a 12- to 16-year review.

We have reviewed 70 Harris-Galante uncemented acetabular components implanted as hybrid hip replacements with cemented stems between 1991 and 1995 in 53 patients whose mean age was 40 years (19 to 49). The mean follow-up was for 13.6 years (12 to 16) with no loss to follow-up. We assessed the patients both clinically and radiologically. The mean Oxford hip score was 20 (12 to 46) and the mean H...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of bone and joint surgery. American volume

دوره 86-A 8  شماره 

صفحات  -

تاریخ انتشار 2004