Equivalence of the bioimpedance and thermodilution methods in measuring cardiac output in hospitalized patients with advanced, decompensated chronic heart failure.
نویسندگان
چکیده
BACKGROUND An accurate and reliable noninvasive method for determining cardiac output/cardiac index would be valuable for patients with acutely decompensated advanced systolic heart failure. OBJECTIVES To determine whether a correlation exists for cardiac output and index determined by using bioimpedance and thermodilution in patients with acutely decompensated complex heart failure and if differences between results with the 2 methods could be explained by the patients' advanced condition. METHODS Cardiac output and index were determined by using bioimpedance and thermodilution in 33 patients. Echocardiographic and electrocardiographic data were assessed to determine if differences between results with the 2 methods could be explained by the patients' advanced condition. Concordance correlation coefficients and Bland-Altman agreement between methods were calculated. RESULTS Four patients were excluded from analysis because reliable measurements could not be obtained; the remaining 29 patients constituted the study population. Mean cardiac outputs determined by thermodilution and bioimpedance were 5.48 and 5.40 L/min, respectively (rhoc = 0.89, P < .001), and mean cardiac indexes were 2.67 and 2.65 (rhoc = 0.82, P < .001). Mean bias (limits of agreement) between data pairs was 0.08 (-0.18 to 0.35) L/min (P = .52) for cardiac output and 0.03 (-0.097 to 0.16; P = .61) for cardiac index. Six data pairs (21%) had an absolute percent difference greater than 15%. Of these, 50% had a higher thermodilution value. CONCLUSION Determinations of cardiac output and index by both methods were significantly correlated. Mean bias between the 2 methods was small, suggesting clinical utility for bioimpedance in patients with complex decompensated heart failure.
منابع مشابه
THE EFFECT OF SLEEP HYGIENE EDUCATION ON SLEEP QUALITY OF PATIENTS WITH HEART FAILURE HOSPITALIZED IN CARDIAC CARE UNITS OF URMIA TEACHING HOSPITALS 2017-2018
Background & Aim: Heart failure is considered one of the most common chronic illnesses in the whole world and is associated with many symptoms due to heart failure in the bloodstream. This study was a clinical trial with the aim of determining the effect of sleep health education on the quality of sleep in patients with heart failure hospitalized in cardiac care units of Orumiyeh educational ce...
متن کاملAccuracy and Reliability of Non-invasive Cardiac Output: The Future in Cardiology?
A new generation of non-invasive cardiac output monitors provides an alternative to using conventional invasive methods such as thermodilution and direct Fick. The Bioz.com measures changes in thoracic electrical bioimpedance (TEB) of the descending aorta. The Innocor uses the principle of inert gas rebreathing. Simultaneous TEB and thermodilution cardiac output measurements were taken from 27 ...
متن کاملAccurate, noninvasive continuous monitoring of cardiac output by whole-body electrical bioimpedance.
STUDY OBJECTIVES Cardiac output (CO) is measured but sparingly due to limitations in its measurement technique (ie, right-heart catheterization). Yet, in recent years it has been suggested that CO may be of value in the diagnosis, risk stratification, and treatment titration of cardiac patients, especially those with congestive heart failure (CHF). We examine the use of a new noninvasive, conti...
متن کاملComparison of cardiac output determined by bioimpedance, thermodilution, and the Fick method.
BACKGROUND Cardiac output can be determined by using a variety of methods. OBJECTIVES To determine the precision and bias between 3 methods for determining cardiac output: bioimpedance, thermodilution, and the Fick method. METHODS Cardiac output was determined by using bioimpedance via neck and thorax patches and thermodilution via pulmonary artery catheter in 46 patients in the intensive c...
متن کاملNon-invasive determination of cardiac output by Doppler echocardiography and electrical bioimpedance.
Cardiac output measured by thermodilution in 25 patients within 24 hours of acute myocardial infarction was compared with cardiac output measured by Doppler echocardiography (24 patients) and electrical bioimpedance (25 patients). The mean (range) cardiac outputs measured by Doppler (4.03 (2.2-6.0) 1/min) and electrical bioimpedance (3.79 (1.1-6.2) 1/min) were similar to the mean thermodilution...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- American journal of critical care : an official publication, American Association of Critical-Care Nurses
دوره 13 6 شماره
صفحات -
تاریخ انتشار 2004