Prostate brachytherapy seed localization using a mobile c-arm without tracking.
نویسندگان
چکیده
The success of prostate brachytherapy depends on the faithful delivery of a dose plan. In turn, intraoperative localization and visualization of the implanted radioactive brachytherapy seeds enables more proficient and informed adjustments to the executed plan during therapy. Prior work has demonstrated adequate seed reconstructions from uncalibrated mobile c-arms using either external tracking devices or image-based fiducials for c-arm pose determination. These alternatives are either time-consuming or interfere with the clinical flow of the surgery, or both. This paper describes a seed reconstruction approach that avoids both tracking devices and fiducials. Instead, it uses the preoperative dose plan in conjunction with a set of captured images to get initial estimates of the c-arm poses followed by an auto-focus technique using the seeds themselves as fiducials to refine the pose estimates. Intraoperative seed localization is achieved through iteratively solving for poses and seed correspondences across images and reconstructing the 3D implanted seeds. The feasibility of this approach was demonstrated through a series of simulations involving variable noise levels, seed densities, image separability and number of images. Preliminary results indicate mean reconstruction errors within 1.2 mm for noisy plans of 84 seeds or fewer. These are attained for additive noise whose standard deviation of the 3D mean error introduced to the plan to simulate the implant is within 3.2 mm.
منابع مشابه
Brachytherapy seed reconstruction with joint-encoded C-arm single-axis rotation and motion compensation
C-arm fluoroscopy images are frequently used for qualitative assessment of prostate brachytherapy. Three-dimensional seed reconstruction from C-arm images is necessary for intraoperative dosimetry and quantitative assessment. Seed reconstruction requires accurately known C-arm poses. We propose to measure the C-arm rotation angles and computationally compensate for inevitable C-arm motion to co...
متن کاملIntra-operative 3D Guidance in Prostate Brachytherapy Using a Non-isocentric C-arm
Intra-operative guidance in Transrectal Ultrasound (TRUS) guided prostate brachytherapy requires localization of inserted radioactive seeds relative to the prostate. Seeds were reconstructed using a typical C-arm, and exported to a commercial brachytherapy system for dosimetry analysis. Technical obstacles for 3D reconstruction on a non-isocentric C-arm included pose-dependent C-arm calibration...
متن کاملDynamic Dosimetry and Edema Detection in Prostate Brachytherapy - a Complete System
Purpose: Brachytherapy (radioactive seed insertion) has emerged as one of the most effective treatment options for patients with prostate cancer, with the added benefit of a convenient outpatient procedure. The main limitation in contemporary brachytherapy is faulty seed placement, predominantly due to the presence of intraoperative edema (tissue expansion). Though currently not available, the ...
متن کاملProstate Brachytherapy Seed Reconstruction Using C-Arm Rotation Measurement and Motion Compensation
During prostate brachytherapy, C-arm flouroscopy images are used for a qualitative assessment of the procedure. Three dimensional reconstruction of the implanted seeds can be used for intraoperative dosimetry and quantitative assessment. Accurate C-arm pose estimation is necessary for 3D localization of the seeds. We propose to measure the C-arm rotation angles and computationally compensate th...
متن کاملLocalization of Brachytherapy Seeds in Ultrasound by Registration to Fluoroscopy
Motivation: In prostate brachytherapy, transrectal ultrasound (TRUS) is used to visualize the anatomy, while implanted seeds can be seen in C-arm fluoroscopy or CT. Intra-operative dosimetry optimization requires localization of the implants in TRUS relative to the anatomy. This could be achieved by registration of TRUS images and the implants reconstructed from fluoroscopy or CT. Methods: TRUS...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Proceedings of SPIE--the International Society for Optical Engineering
دوره 7261 شماره
صفحات -
تاریخ انتشار 2009