Measurement of sodium in albumin solutions with ion-selective electrodes.

نویسندگان

  • M S Mohan
  • R G Bates
  • J M Hiller
  • M J Brand
چکیده

We have investigated the variations in the potentials of sodium-selective glass-membrane electrodes in various concentrations of albumin. These protein solutions serve as a simple model for measurements of electrolytes in whole blood, plasma, or serum with such an electrode. The results indicate that albumin-sodium binding and variations in liquid-junction potentials are of negligible importance. Mostly, the effect of albumin on the sodium glass-electrode potential is attributable to variations in the activity of sodium, determined by the water content of the solutions. We have calculated apparent fractional protein volumes in albumin solutions from measurements of sodium glass-electrode potential and find they compare well with the classical McLean-Hastings formulation. Our results indicate the need to correct experimentally determined potentiometric electrolyte concentrations for protein volumes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Response of ion-selective sodium and potassium electrodes in the Beckman Astra 4 and Astra 8 analyzers.

We tested the response of ion-selective sodium and potassium electrodes that are a part of the new multi-channel chemical analyzers, Astra 8 and Astra 4 (Beckman). For this we used plain and albumin-containing aqueous solutions of known Na+ and K+ concentrations, varied inversely so we could assess how the concentration of each electrolyte would affect the response of the other electrode. The s...

متن کامل

Effect of pH and NaCl on measurements of ionized calcium in matrices of serum and human albumin with a new calcium-selective electrode.

A neutral ligand ion-exchanger type of ion-selective electrode is used in the current version of the Orion Model SS-20 calcium analyzer. We evaluated it over the pH range 4.0 to 8.5, using albumin solutions containing 150 mmol/L NaCl and pooled patients' serum. Within this pH range response was nernstian, and the relationship between potential (in millivolts) and log [Ca2+] at each pH was linea...

متن کامل

Potassium-specific ion-exchanger microelectrodes to measure K + activity in the renal distal tubule.

The recent introduction of miniature liquid ion-exchanger electrodes provides the possibility of overcoming previously encountered limitations on the measurement of specific ionic activities in biological fluids. Hydrogen ion and sodium ion activities have been stuccessfully determined by means of glass-membrane electrodes(l-5). However, in the presence of sodium, glass electrodes are usually i...

متن کامل

Comparison of the vanadyl-selective electrodes prepared by sol–gel and PVC membrane techniques

Sol-gel and polymeric membrane electrodes, based on thiacalix[4]arene as a neutral carrier, weresuccessfully developed for the detection of VO2+ in aqueous solutions. The sol-gel and PVCmembrane electrodes exhibited linear response with Nernstian slopes of 29.3 and 28.4 mV perdecade, respectively, within the vanadyl ion concentration ranges from 1.0 × 10-6 to 1.0 × 10-1mol dm-3 and from 1.0 × 1...

متن کامل

Measurement and Modeling of Mean Ionic Activity Coefficient in Aqueous Solution Containing NaNO3 and Poly Ethylene Glycol

Potentiometric investigation on {H2O+NaNO3+PEG1500} mixtures were made at T=308.15K, using electrochemical cells with two ion-selective electrodes, (Na+ glass) as the cation ion-selective electrode against (NO3- solvent-polymer PVC) as the anion ion-selective electrode. The mean ionic activity coefficients of NaNO3 were measu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 24 4  شماره 

صفحات  -

تاریخ انتشار 1978