Bacterial Contamination of Anaesthetic and Vasopressor Drugs in the Operating Theatres: Ameliyathanelerde Anestetik ve Vazopressör İlaçların Bakteriyel Kontaminasyonu.

نویسندگان

  • Rongrong Rueangchira-Urai
  • Panthila Rujirojindakul
  • Alan Frederick Geater
  • Edward McNeil
چکیده

OBJECTIVE The aim of this study was to determine the incidence of bacterial and fungal contamination in anaesthetic and vasopressor drugs before and after use in operating theatres. METHODS A cross-sectional study was conducted in the operating theatres of a university hospital. We collected 945 samples of three different drugs, namely, propofol, vecuronium and ephedrine, from 20 operating rooms and refrigerators where the unused drugs were stored. Each drug was divided into two groups, the pre-use group and the post-use group. The pre-use drugs were cultured before the patient received the drug. The post-use drugs were cultured after the patient had received the drug or after the drugs had been transferred to other syringes. The culture results were reported as either positive or negative. RESULTS Out of the 945 drug samples, 26 (2.8%, 95% confidence interval=1.8%-4.0%) gave a positive culture. Of the 317 propofol samples, 20 (6.3%) were found to have bacterial contamination, 11 in the pre-use group and 9 in the post-use group. Of the 318 ephedrine samples, 6 (1.9%) were found to be positive on culture, one in the pre-use group and five in the post-use group. Vecuronium gave no positive cultures. All organisms were non-pathogenic, and no fungal contamination was found. CONCLUSION The incidence of bacterial contamination in anaesthetic and vasopressor drugs was 2.8%. Anaesthetic teams must be aware of contamination issues in anaesthetic drugs that have been prepared for later use and, in order to reduce the risk of contamination, they must improve the methods of administering drugs to patients.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Efficacy of a water-based disinfectant on reduction of egg shell bacterial contamination

SÜ Veteriner Fakültesi Yumurtacı Tavuk Çiftliğinden elde edilen yumurtalarda su bazlı dezenfektanla püskürtme tarzında muamelenin kontaminant bakteri sayısına etkisi ölçüldü. Toplam 80 yumurta kullanıldı. Kontrol ve PotoClean® ile dezenfekte edilen uygulama grubu yumurtalarında aerobik ve Gram negatif bakteri sayıları konvansiyonel teknikler ile belirlendi. Aerobik ve Gram negatif bakteri sayıl...

متن کامل

The effect of ventilation system design on air contamination with halothane in operating theatres.

By measuring the halothane concentrations in samples of air from three different operating theatres during routine operating lists the pattern of spread of the waste anaesthetic gases has been demonstrated. The results show that in all the theatres there was a spread of halothane from its point of escape from the anaesthetic circuit to all parts of the theatre air. A turbulent flow ventilation ...

متن کامل

Operating room air pollution: influence of anaesthetic circuit, vapour concentration, gas flow and ventilation.

Atmospheric halothane was sampled from three selected operating theatres and anaesthetic rooms during the middle of operating sessions. Two of the operating theatres studied were ventilated with total air exchange once every six minutes; the third operating theatre had no ventilation. End-tidal samples were obtained from anaesthetists. Halothane vapour concentrations were analysed by gas-liquid...

متن کامل

Anaesthetic monitoring: clinical practice in anaesthetic rooms and theatres.

Twenty anaesthetic rooms and operating theatres in Northern Ireland were visited in both 1990 and 1992. Data was collected on the availability and use of anaesthetic monitoring. In the anaesthetic rooms there were few pulse oximeters. In the theatres more monitors were available and in use. Some change in practice had occurred between 1990 and 1992, notably an increase in the monitoring of vent...

متن کامل

Contamination of laryngoscope handles.

Despite use of sterile or disposable laryngoscope blades for each patient, disinfection of laryngoscope handles does not routinely occur, and these devices present a potential route of transmission of pathogens between patients and staff. A total of 192 specimens from 64 laryngoscope handles deemed 'ready for patient use' in the anaesthetic rooms of 32 operating theatres were semiquantitatively...

متن کامل