A radioimmunoassay for human serum myoglobin: method development and normal values.

نویسندگان

  • T G Rosano
  • M A Kenny
چکیده

We describe a radioimmunoassay that will measure both normal and above-normal concentrations of myoglobin in serum. Myoglobin isolated from human pectoralis muscle was purified by (NH4)2SO4 fractionation and Sephadex gel filtration and injected into rabbits to elicit antisera. Myoglobin was radiolabeled by an acylation with [125]-3-(4-hydroxyphenyl) propionic acid N-hydroxysuccinimide ester. With the purified myoglobin and antisera, we then developed a radioimmunoassy that involves simultaneous regent addition, a 3.5-h incubation at 37 degrees C, and separation of the antibody-bound fraction by precipitation with polyethylene glycol. Information is given on detection limit, precision, linearity, recovery, and specimen preservation. Cross-reactivity to human hemoglobin is negligible. Finally, we investigated the possible relationship between serum myoglobin concentration and muscle mass.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radioimmunoassay of myoglobin in human serum. Results in patients with acute myocardial infarction.

A radioimmunoassay has been developed for the measurement of serum myoglobin in order to evaluate the time-course and frequency of myoglobinemia in patients with acute myocardial infarction. The method can detect as little as 0.5 ng of myoglobin and is not affected by hemolysis or storage of serum at -- 20 degrees C. Myoglobin was detected in all of 92 sera from normal adults and ranged between...

متن کامل

Serum myoglobin level as diagnostic test in patients with acute myocardial infarction.

Serum myoglobin levels were measured in normal subjects and patients by means of a newly developed radioimmunoassay. Myoglobin was identified in all of 135 sera from normal adults and ranged between 6 and 85 ng/ml (mean +/- SE 31 +/- 1.3). Raised myoglobin levels were present in 62 of 64 patients with documented acute myocardial infarction, the mean serum concentration being 528 +/- 76 ng/ml. S...

متن کامل

Radioimmunoassay for serum myoglobin.

A column flow-through radioimmune assay for serum myoglobin has been developed. The assay uses antibodies to human or rhesus monkey myoglobin coupled to Sepharose by cyanogen bromide activation and myoglobin labeled by the Chloramine-T method. The labeled myoglobin is stable over two to three half-lives. Serum myoglobin levels were elevated when serum was taken up to 12 hours after myocardial i...

متن کامل

DEVELOPMENT OF A RAPID AND SENSITIVE RADIOIMMUNOASSAY FOR MEASUREMENT OF AFLATOXIN B 1 IN BIOLOGICAL SAMPLES

Aflatoxin B I (AFB) isa well known hepatocarcinogen in several animal species and probably a causative agent in human hepatocellular carcinoma. Humans are exposed to AFB by ingesting contaminated food. Aflatoxin contamination encountered in human foods is usually at low levels which is difficult to measure by chromatographic methods. Therefore in the present study we have developed an immun...

متن کامل

Serum myoglobin and creatine kinase following surgery.

Serum myoglobin (by radioimmunoassay) and creatine kinase were measured for up to 7 days in 30 patients following surgical procedures, including total hip replacement and bilateral subcostal abdominal incisions. Serum myoglobin reached a maximum of 1390 micrograms litre-1 (median 345 micrograms litre-1 for major surgery patients) on the first postoperative day but levels were still elevated by ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 23 1  شماره 

صفحات  -

تاریخ انتشار 1977