Comparison of technetium-99m teboroxime tomography with automated quantitative coronary arteriography and thallium-201 tomographic imaging.

نویسندگان

  • R M Fleming
  • R L Kirkeeide
  • H Taegtmeyer
  • A Adyanthaya
  • D B Cassidy
  • R A Goldstein
چکیده

Technetium-99m (Tc-99m) teboroxime is a new perfusion tracer that is highly extracted and rapidly cleared by the myocardium. To determine the feasibility of Tc-99m teboroxime imaging in the diagnosis of patients with suspected coronary artery disease, 30 patients underwent single photon emission computed tomography imaging with Tc-99m teboroxime (25.2 +/- 1 mCi) at peak exercise and again 60 min later at rest. All patients underwent either a thallium stress test (n = 26) or automated quantitative coronary arteriography (n = 25), or both, without intervening revascularization or infarction. Images were reviewed by two investigators who had no knowledge of clinical data. Coronary lesions with greater than or equal to 50% diameter narrowing by quantitative coronary arteriography were considered significant. Both thallium and Tc-99m teboroxime detected disease in all patients with two or three vessel disease. One vessel disease was detected with Tc-99m teboroxime in 9 of 10 patients and with thallium in 8 of 10 (p = NS). In patients without angiographically significant disease. Tc-99m teboroxime demonstrated normal perfusion in six of eight patients and thallium in three of five (p = NS). Overall, when presence or absence of disease detected by Tc-99m teboroxime or thallium was compared with quantitative coronary arteriography, there was no difference between Tc-99m teboroxime and thallium. These results suggest that Tc-99m teboroxime is comparable to thallium as an imaging agent. The rapid biologic half-life, 5.3 min, allows studies to be completed in 60 to 90 min.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnostic value of a new myocardial perfusion agent, teboroxime (SO 30,217), utilizing a rapid planar imaging protocol: preliminary results.

Technetium-99m-labeled agents have advantages over thallium-201 in terms of photon statistics, cost and clinical availability. They have been suggested as an alternative to thallium for myocardial perfusion imaging. Teboroxime is a new boronic acid adduct of technetium dioxime (BATO) compound that demonstrates favorable characteristics in preliminary studies. With use of a novel (seated) patien...

متن کامل

Risk assessment using single-photon emission computed tomographic technetium-99m sestamibi imaging.

OBJECTIVES This review summarizes the results of single-photon emission computed tomographic (SPECT) technetium-99m (Tc-99m) tracer imaging in patients with stable symptoms, patients with acute coronary syndromes, patients undergoing major non-cardiac surgery and patients with chest pain in the emergency department. BACKGROUND Previous studies have examined the prognostic value of stress thal...

متن کامل

Comparison of technetium-99m tetrofosmin and thallium-201 single-photon emission computed tomographic imaging for detection of myocardial perfusion defects in patients with coronary artery disease.

OBJECTIVES We compared dipyridamole technetium-99m (Tc-99m) tetrofosmin and thallium-201 (Tl-201) single-photon emission computed tomographic (SPECT) imaging with respect to the detection rate of perfusion abnormalities in 26 patients with angiographic coronary artery disease (CAD). BACKGROUND Experimental studies have shown that myocardial extraction of Tc-99m tetrofosmin is lower than that ...

متن کامل

Quantitative rest technetium-99m tetrofosmin imaging in predicting functional recovery after revascularization: comparison with rest-redistribution thallium-201.

OBJECTIVES This study was undertaken to 1) compare the regional myocardial tracer distributions between rest technetium (Tc)-99m tetrofosmin and rest-redistribution thallium (Tl)-201 images in patients with coronary artery disease and left ventricular dysfunction; and 2) assess the comparative values of these agents for predicting functional recovery after revascularization. BACKGROUND Tc-99m...

متن کامل

New Technetium-Labeled Myocardial Perfusion Agents

Radionuclide myocardial perfusion imaging in conjunction with exercise or pharmacologic stress testing is an established technique for diagnosing and assessing the severity of coronary artery disease (1 ). Currently TI is the most widely used radiopharmaceutical for myocardial perfusion imaging. Thallium-201, however, has disadvantages such as low photopeak energy (69-83 keV), which can cause d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 17 6  شماره 

صفحات  -

تاریخ انتشار 1991