Pressure algometry in healthy subjects: inter-examiner variability.
نویسندگان
چکیده
The purpose of this study was to estimate inter-examiner reliability of head and neck algometry. Pain perception thresholds were assessed with a mechanical pressure algometer in 21 healthy individuals. Thresholds were assessed at 13 symmetrical points on each side of the head and neck, at the deltoid muscle and at the median finger. The pressure range of the instrument proved insufficient to study the pain perception threshold on the finger, however. Two different examiners carried out one or two examinations in each subject during one day. The sequence of investigations was varied randomly. The inter-examiner reliability was found to be good, with a mean intra-class correlation coefficient (ICC) of 0.75. Intra-examiner reproducibility was excellent (mean ICC = 0.84). The mean inter-examiner coefficient of variation was 18.7%, while the mean coefficient of repeatability (CR) was 1.60 kg/cm2. In comparison, the mean intra-examiner coefficient of variation was 15% while the mean CR was 1.29 kg/cm2. Statistically significant differences between examiners were found for the frontal point (p < 0.01), while a trend towards lower thresholds in one of the two observers was seen in 10 of the 13 non-significant points. Inter-examiner reliability of side differences was excellent, with CR = 1.23 kg/cm2. In conclusion, manual algometry with a rather inexpensive mechanical device has a good to excellent inter-rater reliability. When studying patients, however, the possible bias introduced by different examiners should be taken into account, both regarding study design and data analysis.
منابع مشابه
Pain pressure threshold algometry of the abdominal wall in healthy women
The objective of this study was to determine the inter- and intra-examiner reliability of pain pressure threshold algometry at various points of the abdominal wall of healthy women. Twenty-one healthy women in menacme with a mean age of 28 ± 5.4 years (range: 19-39 years) were included. All volunteers had regular menstrual cycles (27-33 days) and were right-handed and, to the best of our knowle...
متن کاملPressure algometry is a useful tool to quantify pain in the medial part of the knee: an intra- and inter-reliability study in healthy subjects.
PURPOSE Pain quantification is essential for diagnostic and pain monitoring purposes in disorders around the knee. Pressure algometry is a method described to determine pressure pain threshold (PPT) by applying controlled pressure to a given body point. The purpose of this study was to determine the reliability of this method when it was applied to the medial part of the proximal tibia metaphys...
متن کامل[Bone microindentation and pressure algometry applied to revision total knee replacement and tibial end-of-stem pain. Preliminary results in a group of twenty patients].
OBJECTIVES To study the relationship between the appearance of end-of-stem pain with a preoperative decrease in local bone strength by using the bone microindentation technique. The potential usefulness of pressure algometry in the diagnosis and monitoring of this group of patients is also determined. MATERIAL AND METHOD A preliminary intra- and inter-rater correlation study was performed in ...
متن کاملSingle-Point but Not Tonic Cuff Pressure Pain Sensitivity Is Associated with Level of Physical Fitness – A Study of Non-Athletic Healthy Subjects
Exercise is often used for pain rehabilitation but the link between physical activity level and pain sensitivity is still not fully understood. Pressure pain sensitivity to cuff algometry and conditioned pain modulation (CPM) were evaluated in highly active men (n=22), normally active men (n=26), highly active women (n=27) and normally active women (n=23) based on the Godin Leisure-Time Exercis...
متن کاملDynamic mechanical assessment of muscle hyperalgesia in humans: The dynamic algometer
BACKGROUND Musculoskeletal pain is often associated with a nonhomogeneous distribution of mechanical hyperalgesia. Consequently, new methods able to detect this distribution are needed. OBJECTIVE To develop and test a new method for assessing muscle hyperalgesia with high temporal and spatial resolution that provides complementary information compared with information obtained by traditional ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Scandinavian journal of rehabilitation medicine
دوره 30 1 شماره
صفحات -
تاریخ انتشار 1998