Real-time prostate trajectory estimation with a single imager in arc radiotherapy: a simulation study.
نویسندگان
چکیده
Real-time prostate tracking during intensity-modulated arc radiotherapy requires a reliable prostate position signal during treatment. Many modern linear accelerators have a single gantry-mounted x-ray imager that could be used for intrafraction imaging of implanted prostate markers. The aim of this study was to develop a method to use such a single x-ray imager to estimate the three-dimensional (3D) prostate position in real time during arc treatment delivery and quantify the accuracy of this method in simulations based on 548 prostate trajectories for 17 patients measured with electromagnetic transponders. Imaging at 0.5, 1, 2 and 5 Hz during 360 degrees arc treatments of 1, 2 and 3 min duration was simulated by projecting the prostate position onto the rotating imager. When an image was acquired, a Gaussian probability density function (PDF) for the prostate position was first estimated by maximum likelihood optimization from the set of images acquired so far and then used to estimate the 3D prostate position from the projected position in the image. Since this method needed a PDF right from the onset of the treatment, an initial PDF was obtained with a series of pre-treatment images acquired in 10 s, 20 s or 30 s during a gantry rotation of 60 degrees , 120 degrees or 180 degrees . The accuracy of the estimations was quantified by calculating the root-mean-square (RMS) estimation error for each simulated treatment. The 3D RMS estimation error had a mean value of 0.22 mm and exceeded 1 mm in 0.8% of the cases for 1 min treatments with 5 Hz imaging and 20 s pre-treatment imaging. The position estimation accuracy degraded slightly with reduced imaging frequency or reduced pre-treatment imaging duration. Prolonged treatment duration of 2 and 3 min increased the mean 3D RMS errors to 0.27 mm and 0.30 mm, respectively. The single-imager trajectory estimation method would allow image-guided real-time prostate tracking based on standard equipment for modern linear accelerators.
منابع مشابه
Ball Trajectory Estimation and Robot Control to Reach the Ball Using Single Camera
In robotics research, catching a projectile object with a robotic system is one of the challenging problems. The outcome of these researches can be used in a wide range of applications such as video surveillance systems, analysis of sports videos, monitoring programs for human activities, and human-machine interactions. In this paper, we propose a new vision-based algorithm to estimate the traj...
متن کاملEarly toxicity of moderate hypofractionated volumetric modulated Arc radiotherapy for localized prostate cancer
Background: Based on the radiation biology model of prostate cancer, hypofractionated radiotherapy can improve the treatment outcomes without increasing toxicity. Although hypofractionated radiotherapy is implemented over a short period of time, it is more convenient and cheaper compared with conventional fractionated treatment. The aim of this study was to investigate the early toxicity of mod...
متن کاملMonte Carlo Simulation of Prostate Intensity Modulated Radiotherapy Using PRIMO Software: A Feasibility Study
Introduction: Nowadays Intensity Modulated Radiotherapy (IMRT) is a common method for treating prostate cancers. Must of the Monte Carlo software cannot simulate the IMRT procedures due to inability of these soft wares to simulate the multi leaf collimator (MLC) positions or movements. A new user-friendly software based on the PENELOPE Monte Carlo code named PRIMO was published...
متن کاملOptimization of prostate cancer radiotherapy using of a spacer gel, volumetric modulated arc therapy and a single biological organ at risk objective
Background: The aim was to evaluate the benefit of technical advances for treatment planning: introduction of a hydrogel spacer, VMAT (volumetric modulated arc therapy) and a single biological organ at risk objective for the rectum and bladder. Initial standard was a step-and-shoot IMRT (intensity modulated radiotherapy) without a spacer and conventional organ at risk objectives. Material...
متن کاملTrajectory optimization for dynamic couch rotation during volumetric modulated arc radiotherapy.
Non-coplanar radiation beams are often used in three-dimensional conformal and intensity modulated radiotherapy to reduce dose to organs at risk (OAR) by geometric avoidance. In volumetric modulated arc radiotherapy (VMAT) non-coplanar geometries are generally achieved by applying patient couch rotations to single or multiple full or partial arcs. This paper presents a trajectory optimization m...