Characteristics of the normative database for the Humphrey matrix perimeter.

نویسندگان

  • Andrew John Anderson
  • Chris A Johnson
  • Murray Fingeret
  • John L Keltner
  • Paul G D Spry
  • Michael Wall
  • John S Werner
چکیده

PURPOSE The Humphrey Matrix (Carl Zeiss Meditec, Dublin CA; Welch-Allyn, Skaneateles, NY) is a high-spatial-resolution perimeter that uses frequency-doubling stimuli. It incorporates an efficient test strategy that assumes that age, eccentricity, and test procedure type have only small effects on sensitivity. The results used to create the normative database for the perimeter were examined, to see whether these assumptions were met and to examine the form of the normative data. METHOD Visual fields were measured (Matrix 30-2, 24-2, 10-2 and Macula patterns) in >275 subjects judged to be normal by a battery of clinical procedures. The right eye was always tested first. RESULTS Sensitivity decreased by approximately 0.7 dB per age decade across all eccentricities; sensitivity decreased with eccentricity, typically by <5 dB at the most peripheral points tested. Although there was no systematic difference in sensitivity between the 30-2 and 24-2 tests, the Macula test sensitivities were typically 1 dB higher than for the 10-2 test. Sensitivity in the left eye was slightly lower than in the right, with the difference being significantly greater in the temporal visual field. In most test locations, the 95% confidence interval of normal sensitivity was approximately 6 dB below the median sensitivity. CONCLUSIONS The performance of the test strategy in the Matrix perimeter is appropriately matched to the response characteristics of the normal population. The finding of a spatially nonuniform difference in sensitivity between left and right eyes is attributable to light-adaptation differences between the eyes. This effect is accounted for in the perimeter's normative database.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anatomy of a supergroup: does a criterion of normal perimetric performance generate a supernormal population?

PURPOSE To interpret individual results from automated perimeters, a normative database must be developed. Typically, a set of criteria determines those subjects that may be included in the database. This study examined whether a criterion of normal performance on an established perimeter generates a subgroup with supernormal perimetric performance. METHODS The right-eye perimetric results of...

متن کامل

Visual field examination method using virtual reality glasses compared with the Humphrey perimeter

PURPOSE To present a visual field examination method using virtual reality glasses and evaluate the reliability of the method by comparing the results with those of the Humphrey perimeter. MATERIALS AND METHODS Virtual reality glasses, a smartphone with a 6 inch display, and software that implements a fast-threshold 3 dB step staircase algorithm for the central 24° of visual field (52 points)...

متن کامل

Visual field examination using a video projector: comparison with Humphrey perimeter

PURPOSE To present a method of visual field examination using a video projector. Also, we compare our results with those of a Humphrey perimeter, which is accepted as standard in automated perimetry. MATERIALS AND METHODS Software implementing a full-threshold 4-2-step staircase algorithm for the central 30-2 of the visual field (76 points) has been developed and tested in nine eyes of seven ...

متن کامل

Scaling and Fractal Concepts in Saturated Hydraulic Conductivity: Comparison of Some Models

Measurement of soil saturated hydraulic conductivity, Ks, is normally affected by flow patterns such as macro pore; however, most current techniques do  not differentiate flow types, causing major problems in describing water and chemical flows within the soil matrix. This study compares eight models for scaling Ks and predicted matrix and macro pore Ks, using a database composed of 50 datasets...

متن کامل

Effects of astigmatism on the Humphrey Matrix perimeter.

PURPOSE To evaluate the influence of astigmatism in terms of its amount and direction on the results of Humphrey Matrix perimetry. METHODS A total of 31 healthy volunteers from hospital staff were consecutively recruited to undergo repeat testing with Humphrey Matrix 24-2 full threshold program with various induced simple myopic astigmatism. All subjects had previous experience (at least twic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 46 4  شماره 

صفحات  -

تاریخ انتشار 2005