Correlation of maximum flexion with clinical outcome after total knee replacement in Asian patients.
نویسندگان
چکیده
This study aimed to determine the correlation between the amount of maximum flexion and the clinical outcome in 207 Koreans (333 knees) undergoing total knee replacement. The association of maximum flexion with clinical outcome was evaluated one year postoperatively using three scoring systems; the American Knee Society score, Western Ontario McMaster Universities Osteoarthritis index and the Short Form-36. The mean maximum flexion decreased post-operatively at 12 months from 140.1 degrees (60 degrees to 160 degrees ) to 133.0 degrees (105 degrees to 150 degrees ). Only the social function score of the Short Form-36 correlated significantly with maximum flexion (correlation coefficient = 0.180, p = 0.039). In comparative analyses of subgroups divided by a maximum flexion of 120 degrees , we found no significant differences in any parameters except the social function score of the Short Form-36 (41.9 vs 47.3, p = 0.031). Knees with a maximum flexion of more than 135 degrees had a better functional Western Ontario McMasters Universities Osteoarthritis index score than knees with maximum flexion of 135 degrees or less (17.5 vs 14.3, p = 0.031). We found only weak correlation between the postoperative maximum flexion and the clinical parameters for pain relief, function and quality of life, even in Korean patients. Efforts to increase post-operative maximum flexion should be exercised with caution until concerns relating to high-flexion activities are sufficiently resolved.
منابع مشابه
Improving maximum flexion with a posterior cruciate retaining total knee arthroplasty: a fluoroscopic study.
Achieving a large range of motion (ROM) is a much-desired clinical outcome after total knee arthroplasty (TKA), especially in Asian and Middle Eastern cultures. TKA design plays an important role in providing the post-operative ROM. This study investigated the kinematics of a new high-flexion posterior cruciate ligament retaining total knee replacement, featuring an enlarged posterior condylar ...
متن کاملA prospective randomised double-blind study of functional outcome and range of flexion following total knee replacement with the NexGen standard and high flexion components.
Modifications in the design of knee replacements have been proposed in order to maximise flexion. We performed a prospective double-blind randomised controlled trial to compare the functional outcome, including maximum knee flexion, in patients receiving either a standard or a high flexion version of the NexGen legacy posterior stabilised total knee replacement. A total of 56 patients, half of ...
متن کاملStudy of knee range of motion after soft tissue repair in both flexion and extension during total knee arthroplasty: a randomized clinical trial
Background: The patient's position during the recovery time after arthroplasty surgery can be a factor in reducing complications and improving patients’ condition. Therefore, this study was performed to compare the knee range of motion after soft tissue repair in both flexion and extension positions of total knee arthroplasty. Methods: This study is a double-blind clinical trial. The study pop...
متن کاملActive Flexion in Weight Bearing Better Correlates with Functional Outcomes of Total Knee Arthroplasty than Passive Flexion
PURPOSE Correlations between maximum flexion and functional outcomes in total knee arthroplasty (TKA) patients are reportedly weak. We investigated whether there are differences between passive maximum flexion in nonweight bearing and other types of maximum flexion and whether the type of maximum flexion correlates with functional outcomes. MATERIALS AND METHODS A total of 210 patients (359 k...
متن کاملAnteroposterior Translation Does Not Correlate With Knee Flexion After Total Knee Arthroplasty
BACKGROUND Stiffness after a TKA can cause patient dissatisfaction and diminished function, therefore it is important to characterize predictors of ROM after TKA. Studies of AP translation in conscious individuals disagree whether AP translation affects maximum knee flexion angle after implantation of a highly congruent sphere and trough geometry PCL-substituting prosthesis in a TKA. QUESTION...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 89 5 شماره
صفحات -
تاریخ انتشار 2007