A slice-selective B1-insensitive composite pulse design for improved excitation uniformity at 7 T

نویسندگان

  • J. Moore
  • M. Jankiewicz
  • A. W. Anderson
  • J. C. Gore
چکیده

sub-pulses, each with 32 μs duration; (b) optimized phase modulation waveform; (c) simulated values of transverse magnetization for the optimized pulse over a range of relative B1 magnitudes (horizontal axis) and frequency offsets (vertical axis); (d) simulated frequency profiles for various relative B1 magnitudes. A slice-selective B1-insensitive composite pulse design for improved excitation uniformity at 7 T

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sparse spokes slice selective design for B1 inhomogeneity correction at 7T

Introduction: At high magnetic field strength, B1 inhomogeneity causes undesired effects of non-uniformity in SNR and contrast. For slice selective excitation, 3D RF pulse design proposed in [1,2,3], can be used to mitigate this B1 inhomogeneity effect. These designs are based on playing kz sinc “spokes” of different amplitude at a number of (kx,ky) locations around the k-space origin. The sinc...

متن کامل

An Optimized Composite Refocusing Pulse for Ultra-High Field MRI

Purpose At high magnetic fields, the wavelengths of the RF pulses transmitted in MRI are comparable to the size of the human torso/head [1], which gives rise to inhomogeneous B1 fields. Variations of the RF field can be reduced (for example) by the use of tailored slice-selective pulses optimized for the desired excitation profile [2] based on spokes or an optimized composite pulse with slice s...

متن کامل

Composite Localization with adiabatic slice selective excitation and refocusing (cLASER) for improved 1H MRSI in non uniform B1 fields

INTRODUCTION: H magnetic resonance spectroscopic imaging (MRSI) can be used as a diagnostic tool to distinguish abnormal from normal tissue by obtaining metabolic information which can be used as biomarkers. MRSI can be improved by going to higher field strengths like 7 Tesla which offer increased spectral resolution and SNR. However, at these field strengths the non uniformity of the B1 field ...

متن کامل

High-flip-angle slice-selective parallel RF transmission with 8 channels at 7 T.

At high magnetic field, B(1)(+) non-uniformity causes undesired inhomogeneity in SNR and image contrast. Parallel RF transmission using tailored 3D k-space trajectory design has been shown to correct for this problem and produce highly uniform in-plane magnetization with good slice selection profile within a relatively short excitation duration. However, at large flip angles the excitation k-sp...

متن کامل

Composite Slice-Selective 90' Excitation Pulses with Adiabaticity

Slice-selective adiabatic pulses are mostly confined to spin inversion and refocusing pulses. Here composite slice-selective 90" excitation pulses capable of multi-slice applications are proposed. This new class of pulses are based on halved adiabatic MIP pulses with each segment of the halved MIP pulses replaced by a small flip angle slice-selective plane rotation pulse such as a hamming-filte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009