Direct bone conduction stimulation: Ipsilateral effect of different transducer attachments in active transcutaneous devices
نویسندگان
چکیده
Active transcutaneous bone conduction devices, where the transducer is implanted, are used for rehabilitation of hearing impaired patients by directly stimulating the skull bone. The transducer and the way it is attached to the bone play a central role in the design of such devices. The actual effect of varying the contact to bone has not been addressed yet. The aim of this study is therefore to compare how different attachment methods of the transducer to the bone for direct stimulation affect the ear canal sound pressure and vibration transmission to the ipsilateral cochlea. Three different attachments to the bone were tested: (A) via a flat small-sized surface, (B) via a flat wide surface and (C) via two separated screws. Measurements were done on four human heads on both sides. The attachments were compared in terms of induced cochlear promontory velocity, measured by a laser Doppler vibrometer, and ear canal sound pressure, measured by a low noise microphone. A swept sine stimulus was used in the frequency range 0.1-10 kHz. On an average level, the attachment method seems to affect the transmission mainly at frequencies above 5 kHz. Furthermore, the results suggest that a smaller contact surface might perform better in terms of transmission of vibrations at mid and high frequencies. However, when considering the whole frequency range, average results from the different attachment techniques are comparable.
منابع مشابه
Implantable Audiologic Devices and Facial Plastic Surgery in Elderly Patients
Advances in technology have led to the development of several implantable bone conduction devices (BCD) employing bone conduction stimulation for the treatment and rehabilitation of mixed and conductive hearing loss [1]. BCD are alternatives when the benefit of conventional prosthetic equipment is limited or contraindicated [1,2]. BCDs directly stimulate the inner ear by skull vibration [1]. Bo...
متن کاملNew developments in bone-conduction hearing implants: a review
The different kinds of bone-conduction devices (BCDs) available for hearing rehabilitation are growing. In this paper, all BCDs currently available or in clinical trials will be described in categories according to their principles. BCDs that vibrate the bone via the skin are referred to as skin-drive devices, and are divided into conventional devices, which are attached with softbands, for exa...
متن کاملThe Prediction of Speech Recognition in Noise With a Semi-Implantable Bone Conduction Hearing System by External Bone Conduction Stimulation With Headband
Semi-implantable transcutaneous bone conduction devices are treatment options for conductive and mixed hearing loss (CHL/MHL). For counseling of patients, realistic simulation of the functional result is desirable. This study compared speech recognition in noise with a semi-implantable transcutaneous bone conduction device to external stimulation with a bone conduction device fixed by a headban...
متن کاملA Finite Element Model of the Human Head for Simulation of Bone-conducted Sound
.......................................................................................................... 1 LIST OF PAPERS .................................................................................................. 3 INTRODUCTION .................................................................................................. 5 Background of bone-conducted sound ..........................
متن کاملNormal ipsilateral/contralateral asymmetries in infant multiple auditory steady-state responses to air- and bone-conduction stimuli.
OBJECTIVES Two-channel recordings of infants' air- and bone-conduction auditory brainstem responses to brief tones show ipsilateral and contralateral (to the stimulated ear) asymmetries which may be used to isolate which cochlea is the primary contributor to the response. The objective of this study was to determine whether similar ipsilateral/contralateral asymmetries are also present in the a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Hearing Research
دوره 361 شماره
صفحات -
تاریخ انتشار 2018