Simultaneous dipyridamole/maximal subjective exercise with 99mTc-MIBI SPECT: improved diagnostic yield in coronary artery disease.
نویسندگان
چکیده
OBJECTIVES We attempted to demonstrate that simultaneous dipyridamole administration and maximal subjective exercise in patients who are unable to achieve a good exercise level can improve the diagnostic efficacy of technetium-99m methoxy isobutyl isonitrile (99mTc-MIBI) myocardial single-photon emission computed tomography (SPECT). BACKGROUND The results of myocardial perfusion scintigraphy are unsatisfactory if the level of exercise achieved by the patient is insufficient. The use of dipyridamole with maximal subjective stress testing has been shown to improve the quality of the thallium-201 myocardial perfusion images, but there are no studies demonstrating that this combination improves the diagnostic accuracy of myocardial perfusion SPECT. METHODS Two hundred thirty-one consecutive patients, without a previous myocardial infarction, were classified into three groups: group 1, 91 patients with an adequate exercise test; group 2, 68 patients with an inadequate exercise test; group 3, 72 patients with an inadequate exercise test who then received intravenous dipyridamole (0.56 mg/kg body weight over 4 min) simultaneously with exercise. RESULTS Results for sensitivity (89%) and negative predictive value (83%) in group 3 were significantly better than those in group 2 (71% [p = 0.03] and 56% [p = 0.002], respectively) and not significantly different from those in group 1. The polar maps of 20 patients studied with an without dipyridamole at the same exercise level revealed a significantly greater extent of ischemia in each territory and in a global assessment (19 + 20% vs. 8 + 11%, p < 0.0001) when dipyridamole was administered during physical exercise. CONCLUSIONS Intravenous dipyridamole administration during exercise testing is advisable in all patients who are unable to achieve an adequate exercise level. This approach permits physicians to avoid missing ergometric information while optimizing myocardial SPECT results.
منابع مشابه
Gated 99mTc-MIBI myocardial perfusion SPECT in patients with right bundle branch block but without evidence of coronary artery disease
Introduction: We aimed to investigate the effect of right bundle branch block (RBBB) on perfusion and functional parameters in dipyridamole stress/rest Tc99m-MIBI gated myocardial perfusion SPECT (GSPECT) which may be helpful in interpretation of myocardial perfusion imaging. Methods: We studied 73 patients with low pre-test likelihood of coronary artery disease in two groups: 38 patients wit...
متن کاملQuantitative rotational tomography with 201Tl and 99mTc 2-methoxy-isobutyl-isonitrile. A direct comparison in normal individuals and patients with coronary artery disease.
We tested the hypothesis that 99mTc 2-methoxy-isobutyl-isonitrile (99mTc MIBI), a new radiopharmaceutical for myocardial perfusion imaging, provides accurate noninvasive detection of coronary artery disease (CAD). Imaging in patients after exercise and at rest with 99mTc MIBI was compared with imaging after exercise and redistribution with 201Tl in 12 normal subjects and 38 patients with angiog...
متن کاملSelection of the optimal stress test for the diagnosis of coronary artery disease.
OBJECTIVE To compare the value and limitations of exercise testing, dipyridamole echocardiography, dobutamine-atropine echocardiography, and MIBI-SPECT (technetium-99m methoxyisobutyl nitrile single photon emission computed tomography) during dobutamine infusion in the diagnosis of coronary artery disease. DESIGN The performance of these four tests was assessed in random order on a consecutiv...
متن کاملNoninvasive diagnosis of coronary artery stenosis in women with limited exercise capacity: comparison of dobutamine stress echocardiography and 99mTc sestamibi single-photon emission CT.
OBJECTIVES To compare the accuracy of dobutamine stress echocardiography (DSE) and simultaneous 99mTc sestamibi (MIBI) single-photon emission CT (SPECT) imaging for the diagnosis of coronary artery stenosis in women. PATIENTS Seventy women with limited exercise capacity referred for evaluation of myocardial ischemia. METHODS DSE (up to 40 microg/kg/min) was performed in conjunction with str...
متن کاملGated myocardial perfusion SPECT in patients with left bundle block but having low probability of coronary artery disease; as compared to the patients with normal electrocardiogram
Introduction: We aimed to investigate of effect of left bundle branch block (LBBB) on perfusion and functional parameters in dipyridamole Tc99m-MIBI gated myocardial perfusion SPECT which may be helpful in interpretation of myocardial perfusion imaging. Methods: We studied 70 patients with low pre-test probability of coronary artery disease in two groups: 35 patients with LBBB and 35 subject...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of the American College of Cardiology
دوره 29 3 شماره
صفحات -
تاریخ انتشار 1997