Does fluoroscopy improve acetabular component placement in total hip arthroplasty?

نویسندگان

  • Brandon S Beamer
  • Jordan H Morgan
  • Christopher Barr
  • Michael J Weaver
  • Mark S Vrahas
چکیده

BACKGROUND The success of THA largely depends on correct placement of the individual components. Traditionally, these have been placed freehand using anatomic landmarks, but studies have shown poor accuracy with this method. QUESTIONS/PURPOSES Specifically, we asked (1) does using fluoroscopy lead to more accurate and greater likelihood of cup placement with the Lewinnek safe zone than does freehand cup placement; (2) is there a learning curve associated with the use of fluoroscopy for cup placement; (3) does the use of fluoroscopy increase operative time; and (4) is there a difference in leg length discrepancy between freehand and fluoroscopic techniques? METHODS This series consisted of 109 consecutive patients undergoing primary THA, conversion of a previous hip surgery to THA, and revision THA during a 24-month period. No patients were excluded from analysis during this time. The first 52 patients had cups placed freehand, and then the next 57 patients had acetabular components placed using fluoroscopy; the analysis began with the first patient treated using fluoroscopy, to include our initial experience with the technique. The abduction, version, and limb length discrepancy were measured on 6-week postoperative pelvic radiographs obtained with the patient in the supine position. Operative time, sex, age, BMI, diagnosis, operative side, and femoral head size were recorded as possible confounders. RESULTS Cups inserted freehand were placed in the ideal range of abduction (30°-45°) and anteversion (5°-25°) 44% of the time. With fluoroscopy, placement in the Lewinnek safe zone for both measures significantly increased to 65%. The odds of placing the cup in the Lewinnek safe zone for abduction and version were 2.3 times greater with the use of fluoroscopy (95% CI, 1.2-5.0; p = 0.03). Patients undergoing primary THAs (32 freehand, 35 C-arm) had cup placement in the safe zone for abduction and version 44% of the time freehand and 57% of the time with fluoroscopy, which failed to reach statistical significance. There was no difference in operative time, patient age, sex, operative side, diagnosis, limb length discrepancy, or femoral head size between the two groups. CONCLUSIONS The use of fluoroscopy to directly observe pelvic position and acetabular component placement increased the success of placement in the Lewinnek safe zone in this cohort of patients having complex and primary THAs. This is a simple, low-cost, and quick method for increasing successful acetabular component alignment. The study population included a large proportion of patients having complex THAs, and further validation of this technique in patients undergoing straightforward, primary THAs needs to be done to understand if similar gains in accuracy for component placement can be expected in that group. LEVEL OF EVIDENCE Level III, therapeutic study. See the Instructions for Authors for a complete description of levels of evidence.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Does Intraoperative Fluoroscopy Improve Component Positioning in Total Hip Arthroplasty?

Accurate placement of components is imperative for successful outcomes after total hip arthroplasty (THA). Although technology-assisted techniques offer the potential for greater accuracy in prosthesis positioning, the need for additional resources prevents their widespread use. The goal of this study was to compare primary THA procedures performed with and without intraoperative fluoroscopic g...

متن کامل

Does Intraoperative Fluoroscopy Improve Component Positioning in Total Hip Arthroplasty?

Accurate placement of components is imperative for successful outcomes after total hip arthroplasty (THA). Although technology-assisted techniques offer the potential for greater accuracy in prosthesis positioning, the need for additional resources prevents their widespread use. The goal of this study was to compare primary THA procedures performed with and without intraoperative fluoroscopic g...

متن کامل

Acetabular component positioning in primary THA via an anterior, posterolateral, or posterolateral-navigated surgical technique.

The purpose of this study was to compare the acetabular component alignment in patients undergoing primary total hip arthroplasty (THA) via 3 surgical techniques: direct anterior using intraoperative fluoroscopy, posterolateral using an external alignment guide (posterolateral conventional), and posterolateral using computer navigation (posterolateral navigated). Two surgeons performed the dire...

متن کامل

Acetabular Placement Accuracy With the Direct Anterior Approach Freehand Technique.

BACKGROUND Acetabular cup placement in total hip arthroplasty (THA) has been recognized as an important factor in operative success, and accurate cup placement has been the impetus for novel medical technologies. METHODS This article examines the cup placement in 955 THAs using a freehand Direct Anterior Approach on a standard operating table. Acetabular anteversion and inclination were deter...

متن کامل

Patient-specific instrumentation improves the accuracy of acetabular component placement in total hip arthroplasty.

AIMS Accurate placement of the acetabular component during total hip arthroplasty (THA) is an important factor in the success of the procedure. However, the reported accuracy varies greatly and is dependent upon whether free hand or navigated techniques are used. The aim of this study was to assess the accuracy of an instrument system that incorporates 3D printed, patient-specific guides design...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical orthopaedics and related research

دوره 472 12  شماره 

صفحات  -

تاریخ انتشار 2014