Mapping apparent eccentricity and residual ensemble anisotropy in the gray matter using angular double-pulsed-field-gradient MRI.

نویسندگان

  • Noam Shemesh
  • Daniel Barazany
  • Ofer Sadan
  • Leah Bar
  • Yuval Zur
  • Yael Barhum
  • Nir Sochen
  • Daniel Offen
  • Yaniv Assaf
  • Yoram Cohen
چکیده

Conventional diffusion MRI methods are mostly capable of portraying microarchitectural elements such as fiber orientation in white matter from detection of diffusion anisotropy, which arises from the coherent organization of anisotropic compartments. Double-pulsed-field-gradient MR methods provide a means for obtaining microstructural information such as compartment shape and microscopic anisotropies even in scenarios where macroscopic organization is absent. Here, we apply angular double-pulsed-gradient-spin-echo MRI in the rat brain both ex vivo and in vivo for the first time. Robust angular dependencies are detected in the brain at long mixing time (t(m) ). In many pixels, the oscillations seem to originate from residual directors in randomly oriented media, i.e., from residual ensemble anisotropy, as corroborated by quantitative simulations. We then developed an analysis scheme that enables one to map of structural indices such as apparent eccentricity (aE) and residual phase (φ) that enables characterization of the rat brain in general, and especially the rat gray matter. We conclude that double-pulsed-gradient-spin-echo MRI may in principle become important in characterizing gray matter morphological features and pathologies in both basic and applied neurosciences.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microscopic and compartment shape anisotropies in gray and white matter revealed by angular bipolar double-PFG MR.

Diffusion MR has become one of the most important tools for studying neuronal tissues. Conventional single-pulsed-field-gradient methodologies are capable of faithfully depicting diffusion anisotropy in coherently ordered structures, providing important microstructural information; however, it is extremely difficult to characterize randomly oriented compartments using conventional single-pulsed...

متن کامل

Non - invasive average axon diameter mapping using double pulsed field gradient ( d - PFG ) filtered MRI

The diameter of myelinated axons is a critical neurophysiological parameter that scales with nerve conduction velocity. In the spinal cord, axons are somatotopically organized into distinct anatomical regions performing specific functions, and characterized by different diameters and diameter distributions. Measuring axon diameters can shed light on nerve function and pathology. In this study w...

متن کامل

Observation of microscopic diffusion anisotropy in the spinal cord using double-pulsed gradient spin echo MRI.

A double-pulsed gradient spin echo (d-PGSE) filtered MRI sequence is proposed to detect microscopic diffusion anisotropy in heterogeneous specimen. The technique was developed, in particular, to characterize local microscopic anisotropy in specimens that are macroscopically isotropic, such as gray matter. In such samples, diffusion tensor MRI (DTI) produces an isotropic or nearly isotropic diff...

متن کامل

In vivo detection of microscopic anisotropy using quadruple pulsed-field gradient (qPFG) diffusion MRI on a clinical scanner

We report our design and implementation of a quadruple pulsed-field gradient (qPFG) diffusion MRI pulse sequence on a whole-body clinical scanner and demonstrate its ability to non-invasively detect restriction-induced microscopic anisotropy in human brain tissue. The microstructural information measured using qPFG diffusion MRI in white matter complements that provided by diffusion tensor imag...

متن کامل

Diffusion-Weighted MRI as a Probe of Tissue Microstructure

Magnetic resonance imaging (MRI) is an indispensable tool in the diagnosis of many diseases and in monitoring various treatments, functional activation, development, and aging. Sensitizing the MRI signal to diffusional motion of spin-labeled molecules enables the quantification of microstructural parameters that describe the geometry being examined. For example, when there is significant levels...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 68 3  شماره 

صفحات  -

تاریخ انتشار 2012