Performance of a high sensitivity time-of-flight PET ring operating simultaneously within a 3T MR system

نویسندگان

  • Craig S Levin
  • Floris Jansen
  • Tim Deller
  • Sri Harsha Maramraju
  • Alex Grant
  • Andrei Iagaru
چکیده

Stanford University, USA A time-of-flight (TOF)-PET/MR research system installed at Stanford will be used to test the hypotheses that (a) it is possible to acquire simultaneous TOF-PET and 3T MR data while achieving uncompromised performance in both modalities and (b) simultaneous TOF-PET/MR is a tool for multi-parameter characterization of disease. In this paper we will describe the design as well as performance measurements both for the standalone PET ring, and with the two systems integrated. We will also show a selection of clinical images to compare the performance of the integrated TOF-PET/ MR system with that of a state-of-the-art PET/CT system. The silicon photomultiplier (SiPM)-based TOF PET system technology under study was integrated into a modified wide-bore 3T MR scanner. Measurements were performed using the full suite of NEMA NU2-2007 protocols; these protocols were executed with MR on and off to evaluate the influence of MR on the performance of PET. The diagnostic imaging performance was evaluated using subjects who had been already injected with F FDG for a clinically indicated PET/CT exam. The high photon sensitivity and high temporal, energy, and spatial resolutions observed are minimally affected by the concurrent MRI acquisition. Imaging of the first patients showed: (1) High quality images with very low background were achieved, due to the combination of high photon sensitivity, TOF, and long delay post-injection; (2) The combination of high photon sensitivity and high spatial resolution enabled enhanced visualization of small anatomical and abnormal structures; (3) Quantitation of areas of abnormal uptake showed statistically significant increase in SUVmax as expected after the additional uptake time The data indicate that the TOF PET system is capable of excellent performance during simultaneous PET/MR. Comparison of the PET/MR and PET/CT images show equivalent or better quality of the PET images for the PET/MR system.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Recent Advances in PET-MR Hybrid contrast agent

Introduction: All of the Imaging modalities have advantages and disadvantages alone. So if we want to have the best and perfect image, combining these modalities produces something we desired. PET-MR images consist of morphologic and metabolic data. MRI and PET provide high spatial and contrast resolution and high sensitivity and molecular information respectively. Hybrid PET-...

متن کامل

High-resolution, quantitative 3D PET image reconstruction for the Siemens hybrid 3T MR/BrainPET scanner using the PET reconstruction software toolkit (PRESTO)

Institute of Neuroscience and Medicine-4, Forschungszentrum Juelich, Germany The Siemens 3T MR-BrainPET scanner allows us to simultaneously acquire high-resolution MR and PET images thus giving a strong asset for studies of the human brain. Meanwhile, the system is routinely used for MR-PET studies with a variety of radiotracers, e.g. F-FDG, F-FET, C-Raclopride, C-Flumazenil, O-Water. Based on ...

متن کامل

Simultaneous PET and MR Imaging with a Newly Developed 3TMR-BrainPET Scanner

A prototype of a new bimodal scanner was installed in our laboratory. This scanner combines magnetic resonance imaging (MRI) and positron emission tomography (PET) for brain studies. As the PET detector is located within the bore of the MRI scanner, simultaneous measurements become possible. The MR-component consists of a commercial 3T MRI scanner MAGNETOM Tim-Trio, whereas the PET detector Bra...

متن کامل

Simultaneous trimodal MR-PET-EEG imaging for the investigation of resting state networks in humans

RWTH Aachen, Germany Glucose is the principal source of energy for the brain and its relationship to neuronal activity are poorly understood. The human brain uses 80% of its energy for ongoing neural activity that occurs in isolation from any particular stimulus. A promising tool for the investigation of glucose metabolism and its relationship to neuronal activity is simultaneous trimodal MR-PE...

متن کامل

Impact of Time-of-Flight PET/CT with a Large Axial Field of View for Reducing Whole-Body Acquisition Time.

UNLABELLED The aim of this study was to evaluate the imaging performance of 39- and 52-ring time-of-flight (TOF) PET/CT scanners. We also assessed the potential of reducing the scanning time using a 52-ring TOF PET/CT scanner. METHODS PET/CT scanners with 39- and 52-ring lutetium oxyorthosilicate detectors were evaluated. The axial fields of view were 16.2 and 21.6 cm, respectively. We used a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2014