Statistical methods to correct for verification bias in diagnostic studies are inadequate when there are few false negatives: a simulation study

نویسندگان

  • Angel M Cronin
  • Andrew J Vickers
چکیده

BACKGROUND A common feature of diagnostic research is that results for a diagnostic gold standard are available primarily for patients who are positive for the test under investigation. Data from such studies are subject to what has been termed "verification bias". We evaluated statistical methods for verification bias correction when there are few false negatives. METHODS A simulation study was conducted of a screening study subject to verification bias. We compared estimates of the area-under-the-curve (AUC) corrected for verification bias varying both the rate and mechanism of verification. RESULTS In a single simulated data set, varying false negatives from 0 to 4 led to verification bias corrected AUCs ranging from 0.550 to 0.852. Excess variation associated with low numbers of false negatives was confirmed in simulation studies and by analyses of published studies that incorporated verification bias correction. The 2.5th - 97.5th centile range constituted as much as 60% of the possible range of AUCs for some simulations. CONCLUSION Screening programs are designed such that there are few false negatives. Standard statistical methods for verification bias correction are inadequate in this circumstance.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

یک روش جدید برای تصحیح سوگرایی تاییدی در مطالعات بررسی صحت تست‌های تشخیصی با استفاده از رویکرد بیزین

Background & Objectives: One of the problems of diagnostic accuracy studies is verification bias. It occurs when standard test performed only for non-representative subsample of study subjects that diagnostic test done for them. In this study we extend a Bayesian method to correct this bias. Methods: Patients that have had at least twice repeated failures in cycles IVF ICSI were included i...

متن کامل

Modeling and design of a diagnostic and screening algorithm based on hybrid feature selection-enabled linear support vector machine classification

Background: In the current study, a hybrid feature selection approach involving filter and wrapper methods is applied to some bioscience databases with various records, attributes and classes; hence, this strategy enjoys the advantages of both methods such as fast execution, generality, and accuracy. The purpose is diagnosing of the disease status and estimating of the patient survival. Method...

متن کامل

A mixed effect model for bivariate meta-analysis of diagnostic test accuracy studies using a copula representation of the random effects distribution.

Diagnostic test accuracy studies typically report the number of true positives, false positives, true negatives and false negatives. There usually exists a negative association between the number of true positives and true negatives, because studies that adopt less stringent criterion for declaring a test positive invoke higher sensitivities and lower specificities. A generalized linear mixed m...

متن کامل

Computing genetic similarity coefficients from RAPD data: correcting for the effects of PCR artifacts caused by variation in experimental conditions.

The production of informative random amplified polymorphic DNA (RAPD) markers using PCR and a single primer is often accompanied by the generation of artifactual (noninformative) bands as well. When RAPD data are used to compute genetic similarity coefficients, these artifacts (false positives, false negatives, or both) can cause large biases in the numerical values of the coefficients. As a re...

متن کامل

Relationship between Non-Technical Factors and Diagnostic Accuracy of Frozen Section in Axillary Lymph Nodes in Patients with Breast Cancer

Background and purpose: Regional lymph node involvement is one of the main prognostic factors for breast cancer. Intraoperative assessment of sentinel lymph node biopsy (SLNB) by frozen section (FS) allows necessary axillary lymph node dissection (ALND) at the same time. But, false negative results are the main problems of the FS. The aim of this study was to investigate the relationship betwee...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • BMC Medical Research Methodology

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2008