Initial evaluation of automated treatment planning software

نویسندگان

  • Dawn Gintz
  • Kujtim Latifi
  • Jimmy Caudell
  • Benjamin Nelms
  • Geoffrey Zhang
  • Eduardo Moros
  • Vladimir Feygelman
چکیده

Even with advanced inverse-planning techniques, radiation treatment plan opti-mization remains a very time-consuming task with great output variability, which prompted the development of more automated approaches. One commercially available technique mimics the actions of experienced human operators to pro-gressively guide the traditional optimization process with automatically created regions of interest and associated dose-volume objectives. We report on the initial evaluation of this algorithm on 10 challenging cases of locoreginally advanced head and neck cancer. All patients were treated with VMAT to 70 Gy to the gross disease and 56 Gy to the elective bilateral nodes. The results of post-treatment autoplanning (AP) were compared to the original human-driven plans (HDP). We used an objective scoring system based on defining a collection of specific dosimetric metrics and corresponding numeric score functions for each. Five AP techniques with different input dose goals were applied to all patients. The best of them averaged the composite score 8% lower than the HDP, across the patient population. The difference in median values was statistically significant at the 95% confidence level (Wilcoxon paired signed-rank test p = 0.027). This result reflects the premium the institution places on dose homogeneity, which was consistently higher with the HDPs. The OAR sparing was consistently better with the APs, the differences reaching statistical significance for the mean doses to the parotid glands (p < 0.001) and the inferior pharyngeal constrictor (p = 0.016), as well as for the maximum doses to the spinal cord (p = 0.018) and brainstem (p = 0.040). If one is prepared to accept less stringent dose homogeneity criteria from the RTOG 1016 protocol, nine APs would comply with the protocol, while providing lower OAR doses than the HDPs. Overall, AP is a promising clinical tool, but it could benefit from a better process for shifting the balance between the target dose coverage/homogeneity and OAR sparing.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Coverage Path Re-planning for Processing Faults

Currently, an automated surface treatment or finishing (e.g., abrasive blasting, cleaning or painting) is performed in two consecutive steps: first processing by tool, second quality evaluation by sensor. Often, a finished surface has defects like areas not properly processed. This is caused by path inaccuracy or errors in tool deployment. The defected areas can be detected only during a subseq...

متن کامل

Evaluation of health information requirement in management information System

Introduction: Considering the importance of information, providing the management with a reliable information system, can facilitate decision making regarding planning, organizing and controlling. This study aimed to analyze and evaluate information needs of managers at vice - chancellorship for treatment in Iranian medical science universities. Methods: This cross-sectional study was car...

متن کامل

Automating the evaluation of planning systems

Research in automated planning is getting more and more focused on empirical evaluation. Likewise the need for methodologies and benchmarks to build solid evaluations of planners is increasing. In 1998 the planning community made a move to address this need and initiated the International Planning Competition – or IPC for short. This competition has typically been conducted every two years in t...

متن کامل

Hierarchical GUI Test Case Generation Using Automated Planning

ÐThe widespread use of GUIs for interacting with software is leading to the construction of more and more complex GUIs. With the growing complexity come challenges in testing the correctness of a GUI and its underlying software. We present a new technique to automatically generate test cases for GUIs that exploits planning, a well-developed and used technique in artificial intelligence. Given a...

متن کامل

Evaluation of Accuracy and Quality assurance of external beam therapy with photons

Introduction: Receiving exact dose by the patients is vital in radiotherapy. In radiation therapy, the dosimetry of radiations is too important because of successful radiation inquires for delivering the exact dose to the target volume. This study is to evaluate the tolerances and the accuracy of calculated dose of photon beams in the treatment software system. The TECDOC1583 p...

متن کامل

Fragmentation measurement using image processing

In this research, first of all, the existing problems in fragmentation measurement are reviewed for the sake of its fast and reliable evaluation. Then, the available methods used for evaluation of blast results are mentioned. The produced errors especially in recognizing the rock fragments in computer-aided methods, and also, the importance of determination of their sizes in the image analysis ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2016