[Meta analysis of three-dimensional printing patient-specific instrumentation versus conventional instrumentation in total knee arthroplasty].

نویسندگان

  • J T Ren
  • C Xu
  • J S Wang
  • X L Liu
چکیده

Objective: To evaluate the effects of three-dimensional printing patient-specific instrumentation(PSI) versus conventional instrumentation(CI) in the total knee arthroplasty. Methods: According to "patient-specific" , "patient-matched" , "custom" , "Instrumentation" , "Guide Instrumentation" , "cutting blocks" , "total knee arthroplasty" , "total knee replacement" , "TKA" and "TKR" , the literature on PubMed, EMbase, Cochrane library, CBM and WanFang were searched. According to the inclusion and exclusion criteria, the high quality randomized control trial (RCT) studies about three-dimensional (3D) printing patient-specific instrumentation versus conventional instrumentation in the total knee arthroplasty were collected. The post-operative limb mechanical axis outlier, the position of the components outlier, post-operative knee function, operative time, post-operative blood transfusion and complications were analyzed by RevMan 5.3 software. Results: A total of 13 high quality RCT studies were included. The results of Meta-analysis show that there were no statistical differences in the post-operative limb mechanical axis outlier(Z=0.55, P=0.58, 95% CI: 0.78 to 1.56), femoral coronal component outlier(Z=0.38, P=0.71, 95% CI: 0.69 to 1.72), tibia coronal component outlier(Z=1.95, P=0.05, 95% CI: 1.00 to 3.38), femoral rotation angle outlier(Z=0.36, P=0.72, 95% CI: 0.49 to 1.64), post-operative knee function(Z=1.18, P=0.24, 95% CI: -0.66 to 2.63), post-operative blood transfusions(Z=0.74, P=0.46, 95% CI: -0.10 to 0.05) and complications(Z=0.18, P=0.86, 95%CI: -0.07 to 0.05) between the PSI group and the CI group. But there are statistical differences in the operation time(Z=2.66, P=0.01, 95% CI: -15.97 to -2.41)and tibia sagittal component outlier (Z=3.69, P=0.00, 95% CI: 1.43 to 3.18)between the PSI group and the CI group. Conclusions: In the primary total knee arthroplasty the PSI is not superior over the CI for the knee without severe knee varus or valgus deformity or contracture deformity, without the deformity around the knee and without the knee bone loss and obesity. The use of PSI in the primary total knee arthroplasty are not recommend.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Clinical, Functional, and Radiological Outcomes of Total Knee Arthroplasty Using Conventional and Patient-Specific Instrumentation

Background: Recently, patient-specific instrumentation (PSI) systems have been developed in order to increase theaccuracy of component positioning during total knee arthroplasty (TKA); however, the findings of previous studies arecontroversial in this regard. In the current randomized clinical study, the outcomes of computer tomography (CT)-basedPS (patient specific)-guided TK...

متن کامل

Review article: Patient-specific versus standard instrumentation for total knee arthroplasty.

This meta-analysis reviewed 12 studies comparing patient-specific instrumentation (PSI) with standard instrumentation (SI) for total knee arthroplasty in terms of postoperative coronal alignment and operation time. There is no significant difference between PSI and SI in terms of hip-knee-ankle angle (overall coronal alignment or mechanical axis), tibial coronal alignment, and operation time.

متن کامل

Accuracy of patient-specific instrumentation compared with conventional instrumentation in total knee arthroplasty.

Patient-specific instrumentation (PSI) has recently been introduced to improve the alignment following total knee arthroplasty (TKA). However, controversy remains between PSI and conventional instrumentation. The aim of this study is to compare the accuracy of PSI with conventional instruments for total knee arthroplasty (TKA). A systematic literature search was performed in databases including...

متن کامل

Patient-specific instrumentation does not improve radiographic alignment or clinical outcomes after total knee arthroplasty

Background and purpose - Patient-specific instrumentation (PSI) for total knee arthroplasty (TKA) has been introduced to improve alignment and reduce outliers, increase efficiency, and reduce operation time. In order to improve our understanding of the outcomes of patient-specific instrumentation, we conducted a meta-analysis. Patients and methods - We identified randomized and quasi-randomized...

متن کامل

Current data do not support routine use of patient-specific instrumentation in total knee arthroplasty.

The purpose of this systematic review and meta-analysis is to compare patient-specific instrumentation (PSI) versus standard instrumentation for total knee arthroplasty (TKA) with regard to coronal and sagittal alignment, operative time, intraoperative blood loss, and cost. A systematic query in search of relevant studies was performed, and the data published in these studies were extracted and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Zhonghua wai ke za zhi [Chinese journal of surgery]

دوره 55 10  شماره 

صفحات  -

تاریخ انتشار 2016