Intra-observer and inter-observer errors in CT measurement of torsional profiles of lower limbs: a retrospective comparative study

نویسندگان

  • Artemisia Panou
  • Dedorah Faith Stanitski
  • Carl Stanitski
  • Andrea Peccati
  • Nicola Marcello Portinaro
چکیده

BACKGROUND The purpose of this study was to determine errors in measurement of torsional profiles (TP) (torsional femoral angle, torsional tibial angle, and femoral ankle angle) among four orthopedic surgeons, experts, and non-experts in measurement, and the learning curve. METHODS Twenty-six lower extremities of 13 patients with spastic diplegia candidates for femoral/tibial derotational osteotomy had preoperative bilateral computer tomography (CT) scan grams to establish the TP. Each measurement was done by four orthopedic surgeons, two experienced clinicians and interpreters of CT imaging and two with limited clinical and imaging assessment experiences. Images were blinded and the surgeons made three determinations at least 5 days apart; the three angles were measured each time for each limb. Intra-observer and inter-observer variability were determined using bias, standard deviation, and interclass correlation coefficient. RESULTS Significant inter-observer variability and bias were noted between experts and non-experts (average variability: ICC experts: 0.88 ± 0.15; ICC non-experts: 0.91 ± 0.09). For non-experts, excessive bias (25° and 14°) was observed. An associated improvement in bias with additional measurement experience indicated a potential significant learning curve for interpreting these studies. Less inter-observer variability was observed between experts. CONCLUSIONS Measurement of TP is a reliable tool when used by experienced personnel, and their use as a preoperative tool should be reserved to ones with experience with such image assessments. Non-experts' measurements produced a weak agreement when compared to experts'.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inter-observer agreement between 2-dimensional CT versus 3-dimensional I-Space model in the Diagnosis of Occult Scaphoid Fractures

  Background: The I-Space is a radiological imaging system in which Computed Tomography (CT)-scans can be evaluated as a three dimensional hologram. The aim of this study is to analyze the value of virtual reality (I-Space) in diagnosing acute occult scaphoid fractures.   Methods: A convenient cohort of 24 patients with a CT-scan from prior studies, without a scaphoid fracture on radiograph, ye...

متن کامل

Comparing the Accuracy of Cone Beam Computed Tomography,Digital Intraoral Radiography and Conventional Intraoral Radiography in the Measurement of Periodontal Bone Defects

Background and Aim: Cone beam computed tomography (CBCT) produces high-quality data in periodontal diagnosis and treatment planning. The aim of this study was to compare the accuracy of CBCT with intraoral digital and conventional radiography in the measurement of periodontal bone defects.  Methods and Materials: In this diagnostic research, two hundred and eighteen artificial osseous d...

متن کامل

Comparison of Double and Single Leg Weight-Bearing Radiography in Determining Knee Alignment

  Background: Knee malalignment is an important modifiable cause of osteoarthritis (OA). Surgical therapeutic procedures depend on proper knee alignment assessment. The purpose of this study was to compare knee alignment parameters between double and single leg weight-bearing radiographs and to evaluate the reproducibility of inter- and intra-observer measurements. Methods: One hundred eight p...

متن کامل

بررسی میزان خطا در تعیین نقاط سفالومتریک آنالیز Delaire

The architectural and structural analysis of Delaire was developed to evaluate complex craniofacial structures without relating the individual to a so-called normal or average group. This analysis is especially valuable in two regards: first, this analysis is based upon mutual balance of the cranial and facial structures; second, statistical averages are avoided. But , the p...

متن کامل

بررسی مقایسه‌ای دقت Cone beam CT، رادیوگرافی داخل دهانی و پروب پریودنتال در اندازه‌گیری ضایعات استخوانی پریودنتال

Background and Aims: Cone beam computed tomography (CBCT) produces high-quality data about diagnosis and periodontal treatment. To date, there is not enough research regarding periodontal bone measurement using CBCT. The aim of this study was to compare the accuracy of CBCT in measuring periodontal defects to that of intraoral radiography and probing methods.Materials and Methods: Two-hundred a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015