Pars plana vitrectomy with 25-gauge instruments in the treatment of idiopathic epiretinal membranes.

نویسنده

  • C Valmaggia
چکیده

BACKGROUND The sutureless pars plana vitrectomy (ppv) using a 25-gauge instrumentation is a minimally invasive technique which is mainly performed for procedures that do not require extensive vitreous dissection. In a consecutive case series with retrospective collection of data, the advantages and the risks of this technique are discussed in comparison with the conventional 20-gauge ppv for patients with idiopathic epiretinal membranes. PATIENTS AND METHODS Between July 2003 and November 2004, 64 consecutive patients (26 men, 38 women, mean age: 72 years) were treated with a 20-gauge ppv, and between December 2004 and January 2006, 75 consecutive patients (42 men, 33 women, mean age: 70.4 years) were treated with a 25-gauge ppv. The patients were classified into three groups: ppv combined with phacoemulsification (group 1), ppv in pseudophakic eyes (group 2), or ppv without phacoemulsification (group 3). There were postoperative controls after at least 1, 30 and 180 days. RESULTS The visual acuity improves quicker in the groups 1 and 2 of the 25-gauge ppv compared with the 20-gauge ppv due to less postoperative inflammation and to the practical absence of postoperative astigmatism. In the group 3, after using either a 25-gauge or a 20 gauge ppv, the development of a postoperative cataract restrained the improvement of the visual acuity. The following postoperative complications were noticed using the 25-gauge ppv: transitory hypotonia with an eye pressure < 5 mmHg (9 cases) and with attendant choroidal detachment (3 cases), macular oedema (1 case), and endophthalmitis (1 case); using the 20-gauge ppv: transitory hypertonia (9 cases), macular oedema (2 cases), and retinal detachment (3 cases). CONCLUSIONS The sutureless 25-gauge ppv is advantageous for a quick postoperative recovery of the visual acuity, and may be well combined with cataract surgery. Nevertheless, this technique involves risks and its further evaluation, especially in comparison using a 23-gauge ppv, is indicated.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Advances in Vitreo-retinal Surgery: 23-gauge Sutureless Pars Plana Vitrectomy

Pars plana vitrectomy is one of the most common surgical procedures performed for the treatment of various vitreo-retinal diseases such as retinal detachment, vitreous haemorrhage, proliferative diabetic retinopathy, epiretinal membrane and macular hole. Traditionally, most vitrectomy surgical systems utilise the 20-gauge instruments pars plana vitrectomy includes multiple incisions including p...

متن کامل

Comparison of 23 gauge and 25 gauge PPV in the treatment of epiretinal membranes and macular holes.

The aim of this study was to show the long term recovery after the operative procedure of pars plana vitrectomy (PPV) in patients with epiretinal membranes (ERM) and macular holes. We wanted to show if there is a difference in operative approach and results of 23 and 25 gauge PPV Twenty eight patients underwent to operative treatment of idiopatic ERM and macular holes grade III and IV In our st...

متن کامل

27-Gauge Vitrectomy for Primary Rhegmatogenous Retinal Detachment: Is it Feasible?

Dear Editor, Pars plana vitrectomy (PPV) using the 27-gauge transconjunctival approach is the last frontier of small gauge vitrectomy. Only 1 paper has been published so far describing the use of 27-gauge vitrectomy in a limited number of cases, including epiretinal membranes, idiopathic macular holes, diabetic vitreous haemorrhages, a vitreous biopsy for presumed vitreoretinal lymphoma and a f...

متن کامل

Eccentric Macular Hole after Pars Plana Vitrectomy for Idiopathic Macular Hole: A Case Report

INTRODUCTION Postoperative eccentric macular hole (MH) formation is an uncommon complication after pars plana vitrectomy (PPV) with internal limiting membrane (ILM) peeling for epiretinal membrane or MH treatment. Herein, we present a case of eccentric MH formation after PPV with ILM peeling for MH. CASE DESCRIPTION A 72-year-old female patient underwent 23-gauge PPV with ILM peeling for idio...

متن کامل

Surgical Outcomes of 27-gauge Vitrectomy for a Consecutive Series of 163 Eyes with Various Vitreous Diseases

PURPOSE To evaluate the safety and efficacy of 27-gauge vitrectomy for various vitreoretinal disorders. METHODS In this retrospective comparative study, 163 consecutive eyes with various diseases that underwent 27-gauge pars plana vitrectomy with or without ultraspeed transformer by a single surgeon from June 2012 through December 2014 were analyzed in regard to best-corrected visual acuity, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Klinische Monatsblatter fur Augenheilkunde

دوره 224 4  شماره 

صفحات  -

تاریخ انتشار 2007