Abstract submitted for oral presentation AUTOMATED RESPIRATORY CYCLES SELECTION IMPROVES THE VARIABILITY OF RESPIRATORY MECHANICS MONITORING
نویسندگان
چکیده
submitted for oral presentation AUTOMATED RESPIRATORY CYCLES SELECTION IMPROVES THE VARIABILITY OF RESPIRATORY MECHANICS MONITORING. Vincent Rigo, Estelle Graas, Jacques Rigo 1 Neonatal intensive care, CHU and University of Liège, Belgium 2 Nomics sa, Liège, Belgium. Background: The variability of on-line respiratory mechanics (RM) data decreases its use as a tool to monitor ventilated infants. We postulate that calculating those data only from selected respiratory cycles will decrease the coefficient of variability (CV=SD/mean) below 20%. Methods: In ten ventilated premature infants, we recorded ten minutes RM data from the ventilator in two modes. We used continuous pressure, flow and volume recordings to calculate resistance (R), compliance (C), time constant (τ), tidal volume (tV), C20/C and mechanical work of breathing (W) of isolated respiratory cycles. Evaluation of each cycle was done visually from respiratory loops and continuous waves. Good quality respiratory cycles were selected for analysis. From that evaluation, a software was developed to automatically select optimal cycles and to revaluate the various parameters. Results: 11648 breaths were assessed. The software identified good quality cycles with a specificity of 96-99%. The sensibility of 67% increased to 94% when including breath automatically assigned to a slightly lower degree of quality. In assist control, data calculated from the automated selection (data from the respirator;*p<0,03) had CV’s of: R: 28% (35%), C:17%(31%*), τ:34%, tV 15%(24%*), C20/C:16%(29%*) and W:4%. Visually selected data were similar apart from a higher CV of τ. Results in synchronized intermittent mandatory ventilation are in the same direction. Conclusion: Ventilator on-line RM monitoring can be improved by automated selection of good quality breath cycles. The decreased variability of continuous RM data makes those a more reliable tool to assess ventilatory situations and
منابع مشابه
Innovations in mechanical ventilation.
New features of mechanical ventilators are frequently introduced, including new modes, monitoring techniques, and triggering techniques. But new rarely translates into any measureable improvement in outcome. We describe 4 new techniques and attempt to define what is a new invention versus what is innovative-a technique that significantly improves a measurable variable. We describe and review th...
متن کاملLaboratory diagnosis of fungal infections
Selection of appropriate specimens for culture and microscopic examination is based on the results of clinical and radiographic examination and consideration of the most likely fungal pathogen that may cause such an infection. Specimens should be collected under aseptic conditions or after appropriate cleaning and decontamination of the collection site and rapidly transported to the clinical my...
متن کاملMaintaining Respiratory Health in Cystic Fibrosis Patients
Cystic fibrosis (CF) is an inherited disease that primarily affects the lungs and the digestive system, however, it also affects a number of other organs and systems. More than 90% of mortality of CF patients is due to lung complications. Healthy lungs are important for a long life for people with CF, We will discuss two important topics for maintaining respiratory health. Chronic use of drug...
متن کاملSymmetry of Frequency information in Right and Left Lung sound and Infection Detection in Cystic Fibrosis Patients
Cystic fibrosis (CF) is the most common autosomal recessive disorder in white skinned individuals. Chronic lung infection is the main cause of mortality in this disease. Approximately 60–75 % of adult CF patients frequently suffer from Pseudomonas aeruginosa (PA) infection that is strongly associated with inflammation, lung destruction, and increased mortality. Therefore, CF patients should be ...
متن کاملA Wireless Electronic Esophageal Stethoscope for Continuous Monitoring of Cardiovascular and Respiratory Systems during Anaesthesia
Background: The basic requirements for monitoring anesthetized patients during surgery are assessing cardiac and respiratory function. Esophageal stethoscopes have been developed for this purpose, but these devices may not provide clear heart and lung sound due to existence of various noises in operating rooms. In addition, the stethoscope is not applicable for continues monitoring, and it is u...