Improved parametric image generation using spatial-temporal analysis of dynamic PET studies.
نویسندگان
چکیده
The value of parametric images that represent both spatial distribution and quantification of the physiological parameters of tracer kinetics has long been recognized. However, the inherent high noise level of pixel kinetics of dynamic PET makes it unsuitable to generate parametric images of the microparameters of tracer kinetic model by conventional weighted nonlinear least squares (WNLS) fitting. Based on the concept that both spatial and temporal information should be integrated to improve parametric image quality, a nonlinear ridge regression with spatial constraint (NLRRSC) parametric imaging algorithm was proposed in this study. For NLRRSC, a term that penalizes local spatial variation of parameters was added to the cost function of WNLS fitting. The initial estimates and spatial constraint were estimated by component representation model (CRM) with cluster analysis. A hierarchical cluster with average linkage method was used to extract components. The ridge parameter was determined by linear ridge regression theory at each iteration, and a modified Gauss-Newton algorithm was used for minimizing the cost function. Results from a computer simulation showed that the percent mean square error of estimates obtained by NLRRSC can be decreased by 60-80% compared to that of WNLS. The parametric images estimated by NLRRSC are significantly better than the ones generated by WNLS. A highly correlated linear relationship was found between the ROI values calculated from the microparametric images generated by NLRRSC and estimates from ROI kinetic fitting. NLRRSC provided a reliable estimate of glucose metabolite uptake rate with a comparable image quality compared to Patlak analysis. In conclusion, NLRRSC is a reliable and robust parametric imaging algorithm for dynamic PET studies.
منابع مشابه
Clustering-Based Linear Least Square Fitting Method for Generation of Parametric Images in Dynamic FDG PET Studies
Parametric images generated from dynamic positron emission tomography (PET) studies are useful for presenting functional/biological information in the 3-dimensional space, but usually suffer from their high sensitivity to image noise. To improve the quality of these images, we proposed in this study a modified linear least square (LLS) fitting method named cLLS that incorporates a clustering-ba...
متن کاملDynamic PET denoising with HYPR processing.
HighlY constrained backPRojection (HYPR) is a promising image-processing strategy with widespread application in time-resolved MRI that is also well suited for PET applications requiring time series data. The HYPR technique involves the creation of a composite image from the entire time series. The individual time frames then provide the basis for weighting matrices of the composite. The signal...
متن کاملA PRACTICAL APPROACH TO REAL-TIME DYNAMIC BACKGROUND GENERATION BASED ON A TEMPORAL MEDIAN FILTER
In many computer vision applications, segmenting and extraction of moving objects in video sequences is an essential task. Background subtraction, by which each input image is subtracted from the reference image, has often been used for this purpose. In this paper, we offer a novel background-subtraction technique for real-time dynamic background generation using color images that are taken fro...
متن کاملThe direct calculation of parametric images from dynamic PET data using maximum-likelihood iterative reconstruction.
The aim of this work is to calculate, directly from projection data, concise images characterizing the spatial and temporal distribution of labelled compounds from dynamic PET data. Conventionally, image reconstruction and the calculation of parametric images are performed sequentially. By combining the two processes, low-noise parametric images are obtained, using a computationally feasible pa...
متن کاملAutomated Movement Correction for Dynamic PET/CT Images: Evaluation with Phantom and Patient Data
Head movement during a dynamic brain PET/CT imaging results in mismatch between CT and dynamic PET images. It can cause artifacts in CT-based attenuation corrected PET images, thus affecting both the qualitative and quantitative aspects of the dynamic PET images and the derived parametric images. In this study, we developed an automated retrospective image-based movement correction (MC) procedu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- NeuroImage
دوره 15 3 شماره
صفحات -