Distances between bony landmarks and adjacent nerves: anatomical factors that may influence retractor placement in total hip replacement surgery.
نویسندگان
چکیده
BACKGROUND Retractor placement is a leading cause of intraoperative nerve injury during total hip replacement (THR) surgery. The sciatic nerve, femoral nerve, and superior gluteal nerve are most commonly affected. This study aimed to identify the distances from bony landmarks in the hip to the adjacent nerves on magnetic resonance imaging (MRI) and the associations between anatomical factors and these distances that would guide the placement of retractors during THR surgery, in order to minimize the risk of nerve injury. METHODS We reviewed hip MRIs of 263 adults and recorded the distances from (1) the anterior acetabular rim to the femoral nerve; (2) the superior acetabular rim to the superior gluteal nerve; (3) the posterior acetabular rim to the sciatic nerve; and (4) the greater trochanter to the sciatic nerve. The effects of anatomical factors (i.e., gender, age, body height, body mass index (BMI), pelvic width, and acetabular version and morphology) on these distances were analyzed. RESULTS Distances from bony landmarks to adjacent nerves (in cm) were 2.06 ± 0.44, 2.23 ± 0.28, 1.94 ± 0.81, and 4.83 ± 0.26 for the anterior acetabular rim, superior acetabular rim, posterior acetabular rim, and greater trochanter, respectively, and were shorter in women than in men (P < 0.001). Multivariate analysis identified body height as the most influential factor (P < 0.001). Linear regression demonstrated a strong positive linear correlation between body height and these distances (Pearson's r = 0.808, 0.823, 0.818, and 0.792, respectively (P < 0.001)). CONCLUSIONS The distances from bony landmarks to adjacent nerves provide useful information for placing retractors without causing nerve injury during THR surgery. Shorter patients will have shorter distances from bony landmarks to adjacent nerves, prompting more careful placement of retractors.
منابع مشابه
The role of retraction in direct nerve injury in total hip replacement
OBJECTIVES Acetabular retractors have been implicated in damage to the femoral and obturator nerves during total hip replacement. The aim of this study was to determine the anatomical relationship between retractor placement and these nerves. METHODS A posterior approach to the hip was carried out in six fresh cadaveric half pelves. Large Hohmann acetabular retractors were placed anteriorly, ...
متن کاملEvaluation of an Ultrasound Approach to Overcome Soft-tissue Interference on Digitizing Bony Landmarks in Navigation Assisted Total Hip Arthroplasty (tha)
INTRODUCTION: An imageless Computer-Assisted Navigation System (NAV) in THA has been shown to help increase the accuracy of cup placement [1-2]. NAV relies on the location of the Anterior Superior Iliac Spines (ASISs) and the Pubic Symphysis (PS) to establish the pelvic coordinate system for operation. However, in obese individuals, who account for more than half of the patient population, palp...
متن کاملPersistently High Hip Circumference after Bariatric Surgery Is a Major Hurdle to Successful Hip Replacement
The prevalence of class III obesity (BMI ≥ 40 kg/m(2)) in black women is 18%. As class III obesity leads to hip joint deterioration, black women frequently present for orthopedic care. Weight loss associated with bariatric surgery should lead to enhanced success of hip replacements. However, we present a case of a black woman who underwent Roux-en-Y gastric bypass with the expectation that weig...
متن کاملThe use of computer navigation in hip arthroplasty: literature review and evidence today.
Total hip replacement arthroplasty and hip resurfacing are two of the most successful orthopaedic operations performed worldwide. Critical to the success of these operations is the accurate placement of the components. Correct component alignment reduces mechanical wear and the risk of dislocation. Traditionally, correct component alignment relies on the surgeon referencing from the position of...
متن کاملUltrasound Based Localization of Pelvic Anatomical Coordinate System
INTRODUCTION: In Total Hip Replacement, correct alignment of the acetabular component requires precise localization of the pelvic anatomical coordinate system [1, 2]. Typically, computed tomography and fluoroscopy have been used, in conjunction with implanted fiducials and invasive probing of bony landmarks. In this work, we propose an ultrasound based approach that exploits prior knowledge abo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of orthopaedic surgery and research
دوره 11 شماره
صفحات -
تاریخ انتشار 2016