MALDI imaging of formalin-fixed paraffin-embedded tissues: application to model animals of Parkinson disease for biomarker hunting.
نویسندگان
چکیده
A common technique for the long-term storage of tissues in hospitals and clinical laboratories is preservation in formalin-fixed paraffin-embedded (FFPE) blocks. Such tissues stored for more than five years have not been useful for proteomic studies focused on biomarker discovery. Recently, MS-based proteomic analyses of FFPE showed positive results on blocks stored for less than 2 days. However, most samples are stored for more than one year, and thus our objective was to establish a novel strategy using as a model system 6-hydroxydopamine (6-OHDA) treated rat brain tissues stored in FFPE blocks for more than 9 years. We examined MALDI tissue profiling combining the use of automatic spotting of the MALDI matrix with in situ tissue enzymatic digestion. On adjacent sections, the identification of compounds is carried out by tissue digestion followed by nanoLC/MS-MS analysis. The combination of these approaches provides MALDI direct analysis, MALDI/MS imaging, as well as the localization of a large number of proteins. This method is validated since the analyses confirmed that ubiquitin, trans-elongation factor 1, hexokinase, and the Neurofilament M are down-regulated as previously shown in human or Parkinson animal models. In contrast, peroxidoredoxin 6, F1 ATPase, and alpha-enolase are up-regulated. In addition, we uncovered three novel putative biomarkers, the trans-elongation factor 1 (eEF1) and the collapsin response mediator 1 and 2 from protein libraries. Finally, we validate the CRMP-2 protein using immunocytochemistry and MALDI imaging based on the different ions from trypsic digestion of the protein. The access to archived FFPE tissue using MALDI profiling and imaging opens a whole new area in clinical studies and biomarker discovery from hospital biopsy libraries.
منابع مشابه
Fresh Frozen Versus Formalin-Fixed Paraffin Embedded for Mass Spectrometry Imaging.
Matrix-Assisted Laser Desorption Ionization (MALDI) Mass Spectrometry Imaging (MSI) is fast becoming an industry leading technique as a means of investigating the distributions of protein and peptide molecules directly from sections of tissue. Developing protocols for the analysis of FFPE tissue opens up numerous opportunities for novel biomarker discovery, due to the large number of tissue ban...
متن کاملDirect analysis and MALDI imaging of formalin-fixed, paraffin-embedded tissue sections.
Formalin fixation, generally followed by paraffin embedding, is the standard and well-established processing method employed by pathologist. This treatment conserves and stabilizes biopsy samples for years. Analysis of FFPE tissues from biopsy libraries has been, so far, a challenge for proteomics biomarker studies. Herein, we present two methods for the direct analysis of formalin-fixed, paraf...
متن کاملMolecular Mapping Alzheimer's Disease: MALDI Imaging of Formalin-fixed, Paraffin-embedded Human Hippocampal Tissue
A method for the molecular mapping of formalin-fixed, paraffin-embedded human hippocampal tissue affected by Alzheimer's disease (AD) is presented. This approach utilizes imaging mass spectrometry (IMS) with matrix-assisted laser desorption/ionization (MALDI). The usefulness of this technique in comparing diseased versus nor mal tissue at the molecular level while continuing to maintain topolog...
متن کاملMALDI Imaging Mass Spectrometry Profiling of N-Glycans in Formalin-Fixed Paraffin Embedded Clinical Tissue Blocks and Tissue Microarrays
A recently developed matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI-IMS) method to spatially profile the location and distribution of multiple N-linked glycan species in frozen tissues has been extended and improved for the direct analysis of glycans in clinically derived formalin-fixed paraffin-embedded (FFPE) tissues. Formalin-fixed tissues from normal mouse kidn...
متن کاملMultivariate analyses for biomarkers hunting and validation through on-tissue bottom-up or in-source decay in MALDI-MSI: application to prostate cancer.
The large amount of data generated using matrix-assisted laser desorption/ionization mass spectrometric imaging (MALDI-MSI) poses a challenge for data analysis. In fact, generally about 1.10(8)-1.10(9) values (m/z, I) are stored after a single MALDI-MSI experiment. This imposes processing techniques using dedicated informatics tools to be used since manual data interpretation is excluded. This ...