Determination of elemental compositions by gas chromatography/time-of-flight mass spectrometry using chemical and electron ionization.
نویسندگان
چکیده
Many metabolomic applications use gas chromatography/mass spectrometry (GC/MS) under standard 70 eV electron ionization (EI) parameters. However, the abundance of molecular ions is often extremely low, impeding the calculation of elemental compositions for the identification of unknown compounds. On changing the beam-steering voltage of the ion source, the relative abundances of molecular ions at 70 eV EI were increased up to ten-fold for alkanes, fatty acid methyl esters and trimethylsilylated metabolites, concomitant with 2-fold absolute increases in ion intensities. We have compared the abundance, mass accuracy and isotope ratio accuracy of molecular species in EI with those in chemical ionization (CI) with methane as reagent gas under high-mass tuning. Thirty-three peaks of a diverse set of trimethylsilylated metabolites were analyzed in triplicate, resulting in 342 ion species ([M+H](+), [M-CH(3)](+) for CI and [M](+.), [M-CH(3)](+.) for EI). On average, CI yielded 8-fold more intense molecular species than EI. Using internal recalibration, average mass errors of 1.8 +/- 1.6 mm/z units and isotope ratio errors of 2.3 +/- 2.0% (A+1/A ratio) and 1.7 +/- 1.8% (A+2/A ratio) were obtained. When constraining lists of calculated elemental compositions by chemical and heuristic rules using the Seven Golden Rules algorithm and PubChem queries, the correct formula was retrieved as top hit in 60% of the cases and within the top-3 hits in 80% of the cases.
منابع مشابه
Design, Construction and Calibration of a Laser Ionization Time-of-Flight Mass Spectrometer
A time-of-flight mass spectrometer (TOF-MS) developed in our laboratory at Isfahan University of Technology is described here. The TOF-MS instrument uses laser as the ionization source which provides an opportunity to investigate the ions formed in laser ablation or desorption. The TOF-MS has an ionization chamber containing an accelerator and an ion lens to focus the ions into a one meter line...
متن کاملON-LINE SOLID-PHASE EXTRACTION AND LIQUID CHROMATOGRAPHY/PARTICLE BEAM-MASS SPECTROMETRY FOR DEGRADATION STUDIES OF SOME POLAR PESTICIDES IN WATER
An on-line automated method for photodegradation studies of isoproturon, diuron, atrazine, fenitrothion, and metoxuron by means of liquid chromatography/mass spectrometry (LC/MS) with particle beam (PB) interface is described. Surface water samples were first spiked with 50 µg/l of each pesticide and then exposed to the radiation of the medium-pressure mercury lamp. Next, in regular intervals o...
متن کاملDetermination of PBDEs in human breast adipose tissues by gas chromatography coupled with triple quadrupole mass spectrometry.
The potential of gas chromatography/tandem mass spectrometry with a triple quadrupole analyzer for determination of 12 polybrominated diphenyl ethers in human breast tissues has been investigated. After extraction with hexane, two purification procedures-automated normal-phase high-performance liquid chromatography and solid-phase extraction-were assayed. Both electron impact ionization, in sel...
متن کاملAnti-Asthma effect of an active components group from decoction of Pheretima Aspergillum and its chemical composition characterized by Liquid chromatography-quadrupole time of flight mass spectrometry
The decoction of Pheretima aspergillum is used as a traditional medicine for treatment of asthma in China with a long clinical history. The aim of the study was to investigate the anti-asthma activities of an active components group obtained from the decoction of Pheretima aspergillum in histamine and ovalubumin induced asthma guinea pigs. The incubation period of asthma, serum IFN-γ, IL-4 and ...
متن کاملAnalysis of the chemical composition of the essential oil of Polygonum minus Huds. using two-dimensional gas chromatography-time-of-flight mass spectrometry (GC-TOF MS).
The essential oil in leaves of Polygonum minus Huds., a local aromatic plant, were identified by a pipeline of gas chromatography (GC) techniques coupled with mass-spectrometry (MS), flame ionization detector (FID) and two dimensional gas chromatography time of flight mass spectrometry (GC x GC-TOF MS). A total of 48 compounds with a good match and high probability values were identified using ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Rapid communications in mass spectrometry : RCM
دوره 24 8 شماره
صفحات -
تاریخ انتشار 2010