Automated detection of gait initiation and termination using wearable sensors.

نویسندگان

  • Domen Novak
  • Peter Reberšek
  • Stefano Marco Maria De Rossi
  • Marco Donati
  • Janez Podobnik
  • Tadej Beravs
  • Tommaso Lenzi
  • Nicola Vitiello
  • Maria Chiara Carrozza
  • Marko Munih
چکیده

This paper presents algorithms for detection of gait initiation and termination using wearable inertial measurement units and pressure-sensitive insoles. Body joint angles, joint angular velocities, ground reaction force and center of plantar pressure of each foot are obtained from these sensors and input into supervised machine learning algorithms. The proposed initiation detection method recognizes two events: gait onset (an anticipatory movement preceding foot lifting) and toe-off. The termination detection algorithm segments gait into steps, measures the signals over a buffer at the beginning of each step, and determines whether this measurement belongs to the final step. The approach is validated with 10 subjects at two gait speeds, using within-subject and subject-independent cross-validation. Results show that gait initiation can be detected timely and accurately, with few errors in the case of within-subject cross-validation and overall good performance in subject-independent cross-validation. Gait termination can be predicted in over 80% of trials well before the subject comes to a complete stop. Results also show that the two sensor types are equivalent in predicting gait initiation while inertial measurement units are generally superior in predicting gait termination. Potential use of the algorithms is foreseen primarily with assistive devices such as prostheses and exoskeletons.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Toward Real-Time Automated Detection of Turns during Gait Using Wearable Inertial Measurement Units

Previous studies have presented algorithms for detection of turns during gait using wearable sensors, but those algorithms were not built for real-time use. This paper therefore investigates the optimal approach for real-time detection of planned turns during gait using wearable inertial measurement units. Several different sensor positions (head, back and legs) and three different detection cr...

متن کامل

Estimation of Temporal Gait Parameters Using a Wearable Microphone-Sensor-Based System

Most existing wearable gait analysis methods focus on the analysis of data obtained from inertial sensors. This paper proposes a novel, low-cost, wireless and wearable gait analysis system which uses microphone sensors to collect footstep sound signals during walking. This is the first time a microphone sensor is used as a wearable gait analysis device as far as we know. Based on this system, a...

متن کامل

Groggy Wakeup - Automated Generation of Power-Efficient Detection Hierarchies for Wearable Sensors

We present a framework for the automated generation of power-efficient state detection in wearable sensor nodes. The core of the framework is a decision tree classifier, which dynamically adjusts the activation and sampling rate of the sensors (termed groggy wakeup), such that only the data necessary to determine the system state is collected at any given time. This classifier can be tuned to t...

متن کامل

Gait Analysis Using Wearable Sensors

Gait analysis using wearable sensors is an inexpensive, convenient, and efficient manner of providing useful information for multiple health-related applications. As a clinical tool applied in the rehabilitation and diagnosis of medical conditions and sport activities, gait analysis using wearable sensors shows great prospects. The current paper reviews available wearable sensors and ambulatory...

متن کامل

A survey on Alzheimer’s disease detection using gait analysis

Introduction: Early detection of Alzheimer's disease (AD), as a neurodegenerative disease and the most common cause of dementia in the elderly people, using gait analysis have been particularly noted by researcher in recent years. Because this novel method is non-invasive, less cost, and feasible in non-clinical and laboratory environments. Therefore, in this Meta-Analysis review article, detec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medical engineering & physics

دوره 35 12  شماره 

صفحات  -