Morphology Of Current Of Injury Does Not Predict Long Term Active Fixation ICD Lead Performance
نویسندگان
چکیده
BACKGROUND Currents of injury (COI) have been associated with improved lead performance during perioperative measurements in pacemaker and ICD implants. Their relevance on long term lead stability remains unclear. METHODS Unipolar signals were recorded immediately after active fixation ICD lead positioning, blinded to the implanting surgeon. Signals were assigned to prespecified COI types by two independent investigators. Sensing, pacing as well as changes requiring surgical intervention were prospectively investigated for 3 months. RESULTS 105 consecutive ICD lead implants were studied. All could be assigned to a particular COI with 48 type 1, 43 type 2 and 14 type 3 signals. Pacing impedance at implant was 703.8+/-151.6 Ohm with a significant COI independent drop within the first week. Sensing was 10.6mV+/- 3.7mV and pacing threshold at implant was 0.8+/-0.3mV at 0.5ms at implant. There was no significant difference between COI groups at implant and during a 3 months follow up regarding sensing, pacing nor surgical revisions. CONCLUSIONS Three distinct patterns of unipolar endocardial potentials were observed in active fixation ICD lead implant, but COI morphology did not predict lead performance after 3 months.
منابع مشابه
بررسی اثرات نوروسایکولوژیک ورزش مشت زنی آماتور ایران
Boxing is the favorite sport for adult adolescents and lay people. But the harshness of this sport and the possibility of injury to the head has led to many criticism from religious, medical and athletic assciations. The purpose of the present study was to answer this question: Does amateur boxing lead to neuropsychological impairments ? In order to study the short-term and long-term efects of ...
متن کاملRobot Motion Vision Part II: Implementation
The idea of Fixation introduced a direct method for general recovery of shape and motion from images without using either feature correspondence or optical flow [1,2]. There are some parameters which have important effects on the performance of fixation method. However, the theory of fixation does not say anything about the autonomous and correct choice of those parameters. This paper presents ...
متن کاملHigh Tibial Osteotomy: A Systematic Review and Current Concept
High tibia osteotomy is a common procedure in orthopedic surgery. A precise overview on indications, patients selection, pre-operative planning, surgical technique, methods of fixation, and complications have been presented. This paper focused on the points that should be considered to achieve good long-term outcomes. High tibia osteotomy is a common procedure in orthopedic surgery. A precise o...
متن کاملDetection of lead ions using an electrochemical aptasensor
The aim of this research was to develop a simple, selective and sensitive aptasensor for detection of Pb2+ based on hairpin structure of complementary strand (CS) of aptamer (Apt). Screen printed carbon electrode (SPCE) was electrodeposited by gold nanoparticles to be used as the substrate for the immobilization of Apt-CS. Moreover, gold nanoparticles (AuNPs) and thionine were added to increase...
متن کاملA long-term, prospective, cohort study on the performance of right ventricular pacing leads: comparison of active-fixation with passive-fixation leads
Active-fixation pacing leads allow the use of selective pacing sites. We evaluated their long-term performance versus passive-fixation leads in 199 newly implanted patients (n = 100 active and n = 99 passive). Postoperative pacing thresholds in the active group were higher than in the passive group (0.85 ± 0.31 V vs. 0.53 ± 0.21 V at baseline, P < 0.001). The active thresholds fell to 0.72 ± 0....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 9 شماره
صفحات -