Trace detection of explosives using a membrane-based displacement immunoassay.

نویسندگان

  • S Y Rabbany
  • W J Lane
  • W A Marganski
  • A W Kusterbeck
  • F S Ligler
چکیده

A compact membrane-based displacement immunoassay has been designed for rapid detection of explosive compounds 2,4,6-trinitrotoluene (TNT) and hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) at high femtomole levels. The system consists of activated porous membranes, onto which either TNT or RDX antibodies are immobilized, that are inserted into microreactor columns, incorporated into a flow system. The assay is prepared by saturating the immobilized antibody binding sites with labeled antigen. Target analyte is introduced upstream of the microreactor, while the displacement of labeled antigen is monitored downstream using a fluorometer. The concentration of displaced labeled antigen detected is proportional to the concentration of the target analyte introduced into the system. This system provides a reusable and reagentless sensor, suitable for continuous monitoring of explosives, with an operating lifetime of over 50 positive samples. Multiple assays were performed in approximately 5 min at different flow rates, using membranes saturated with varying antibody concentrations. The membrane-based format exhibited a detection limit of approximately 450 fmol for TNT and RDX (100 microl of 1 ng/ml solution) in laboratory samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A membrane-based displacement flow immunoassay.

The use of a membrane-based continuous flow displacement immunoassay for detection of nanomolar quantities of explosives is demonstrated, and the kinetics of this system are characterized through experimentation. Antibodies of 2,4,6-trinitrotoluene (TNT) are immobilized onto a porous membrane with surface reactive sites designed to facilitate the covalent binding of the antibody. After saturati...

متن کامل

Sampling and Preconcentration for Trace Explosives Detection

A trace explosives detection system typically contains three subsystems: sample collection, preconcentration, and detection. Sample collection of trace explosives (vapor and particulate) through large volumes of airflow helps reduce sampling time while increasing the amount of dilute sample collected. Preconcentration of the collected sample before introduction into the detector improves the se...

متن کامل

Modelling of Displacement Method in Surface Plasmon Resonance Sensing

Existing methods of detecting explosives have many problems in terms of stability, sensitivity, high selectivity, and rapid sensing for any given situation. In this study, we selected a displacement method using a surface plasmon resonance (SPR) immunosensor, which is one of the ways to overcome these problems. In an SPR displacement immunoassay, the methods to realize a high sensitivity were i...

متن کامل

Chapter 1 Applications of Luminescence to Fingerprints and Trace Explosives Detection

Fingerprints and trace explosives detection requires great sensitivity, which is provided by luminescence and appropriate physical and chemical treatments. Ninhydrin, 1,2-indanedione and other chemicals react with the amino acids present in the fingerprint residue. The chemically treated samples, on which the prints are to be detected, are excited with the blue lines 476.5 and 488 nm of an Argo...

متن کامل

On-site Rapid Detection of Trace Non-volatile Inorganic Explosives by Stand-alone Ion Mobility Spectrometry via Acid-enhanced Evaporization

New techniques for the field detection of inorganic improvised explosive devices (IEDs) are urgently developed. Although ion mobility spectrometry (IMS) has been proved to be the most effective method for screening organic explosives, it still faces a major challenge to detect inorganic explosives owing to their low volatilities. Herein, we proposed a strategy for detecting trace inorganic expl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of immunological methods

دوره 246 1-2  شماره 

صفحات  -

تاریخ انتشار 2000