GafChromic XR‐QA film in testing panoramic dental radiography

نویسندگان

  • Robert Y.L. Chu
  • Tin Lam
  • Yongguang Liang
چکیده

The location and field size of the incident X-ray beam in panoramic dental radiography cannot be ascertained visually most of the time. However, these parameters are needed for quality control and dosimetry determination. To alleviate this problem, we tested GafChromic XR-QA film on two panoramic systems. For each system, we used the length of a cross-sectional image of the incident beam and the exposure measurement with a pencil ion chamber to compute the dose-area product. The result was confirmed by direct analysis of a dose distribution on a film. Placement of the ion chamber was determined by the latter images. The GafChromic XR-QA version of radiochromic film has thus been demonstrated to usefully complement a pencil ion chamber in the testing of a panoramic radiography system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Using GafChromic film to estimate the effective dose from dental cone beam CT and panoramic radiography.

OBJECTIVES To demonstrate the feasibility of GafChromic(®) XR-QA2 (ISP Corp., Wayne, NJ) as a dosemeter when performing measurements of the effective dose from three cone beam CT (CBCT) units and to compare the doses from examinations of three common dental clinical situations. A second aim was to compare the radiation doses for three digital panoramic units with the doses for the CBCT units. ...

متن کامل

Reflection spectrometry analysis of irradiated GAFCHROMIC XR type R radiochromic films.

The absorption spectra of the GAFCHROMIC XR type R radiochromic film measured with reflectance spectroscopy have been investigated in order to analyze the dosimetry characteristics of the film. Like the XR type T film, this film features two peaks in its absorption spectrum, approximately at 676 and 618 nm, whose intensities increase with increasing absorbed dose. When the main absorption peak ...

متن کامل

Dosimetric evaluation of GAFCHROMIC® XR type T and XR type R films

The high spatial resolution of radiochromic film makes it ideal for dosimetric measurements and dose distributions in regions of high dose gradient. Intensity-modulated radiation therapy, intravascular brachytherapy, and eye-plaque radiation therapy demand precise spatial dosimetric calculations. Such precision is not possible with conventional dosimeters, such as thermoluminescent dosimeters a...

متن کامل

Suitability of radiochromic films for dosimetry of low energy X‐rays

This study examined the response characteristics of three commercially available radiochromic films when exposed to low energy (50 kVp) X-rays. The aim was to evaluate the films for potential use in 2D dosimetry for a low-kV intraoperative radiotherapy (IORT) device known as the ‘Intrabeam’. Dose-response relationships were obtained for Gafchromic EBT, XR-RV2, and XR-QA film in water at several...

متن کامل

Determining rectal dose through cervix cancer radiotherapy by 9 MV photon beam using TLD and XR type T GAFCHROMIC® Film

Background: The goals of the present research were to investigate the rectal dose during four chosen techniques of cervical cancer radiotherapy and to examine how accurately the treatment planning represents dose measurements, and it’s practicality for routine use as well as, to determine the homogeneity of dose in tumor volume. Materials and Methods: The study was carried out using a Nepton 10...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2007